mirror of
https://github.com/fhem/fhem-mirror.git
synced 2025-02-07 23:09:26 +00:00
JSONMETER: docu corrections, additional obis values e.g. powerProduction
git-svn-id: https://svn.fhem.de/fhem/trunk@4871 2b470e98-0d58-463d-a4d8-8e2adae1ed80
This commit is contained in:
parent
d5f6a7cdc5
commit
41a39fa313
@ -86,6 +86,20 @@ sub JSONMETER_UpdateAborted($);
|
||||
,[1, "0101010800FF", "powerConsumption", 2] #{"obis":"0101010800FF","value":41.42,"unit":"kWh" },
|
||||
,[1, "0101010801FF", "powerConsumptionTariff1", 2] # {"obis":"0101010801FF","value":33.53,"unit":"kWh"},
|
||||
,[1, "0101010802FF", "powerConsumptionTariff2", 2] # {"obis":"0101010802FF","value":33.53,"unit":"kWh"},
|
||||
,[1, "0101010803FF", "powerConsumptionTariff3", 2] # {"obis":"0101010803FF","value":33.53,"unit":"kWh"},
|
||||
,[1, "0101010804FF", "powerConsumptionTariff4", 2] # {"obis":"0101010804FF","value":33.53,"unit":"kWh"},
|
||||
,[1, "0101010805FF", "powerConsumptionTariff5", 2] # {"obis":"0101010805FF","value":33.53,"unit":"kWh"},
|
||||
,[1, "010001080080", "powerConsumptionToday", 1]
|
||||
,[1, "010001080081", "powerConsumptionYesterday", 1]
|
||||
,[1, "010001080082", "powerConsumptionLastWeek", 1]
|
||||
,[1, "010001080083", "powerConsumptionLastMonth", 1]
|
||||
,[1, "010001080084", "powerConsumptionLastYear", 1]
|
||||
,[1, "010002080080", "powerProductionToday", 1]
|
||||
,[1, "010002080081", "powerProductionYesterday", 1]
|
||||
,[1, "010002080082", "powerProductionLastWeek", 1]
|
||||
,[1, "010002080083", "powerProductionLastMonth", 1]
|
||||
,[1, "010002080084", "powerProductionLastYear", 1]
|
||||
,[1, "0101020800FF", "powerProduction", 2]
|
||||
,[1, "010020070000", "voltagePhase1", 1] #{"obis":"010020070000","value":237.06,"unit":"V"},
|
||||
,[1, "010034070000", "voltagePhase2", 1] # {"obis":"010034070000","value":236.28,"unit":"V"},
|
||||
,[1, "010048070000", "voltagePhase3", 1] # {"obis":"010048070000","value":236.90,"unit":"V"},
|
||||
@ -556,16 +570,26 @@ JSONMETER_UpdateAborted($)
|
||||
If the pool interval is omitted, it is set to 300 (seconds). Smallest possible value is 10.
|
||||
<br>
|
||||
With 0 it will only update on "manual" request.
|
||||
<li><code>deviceType</code>
|
||||
<ul>Used to define the path and port to extract the json file.
|
||||
<li><b>ITF</b> - One tariff power meter used by N-ENERGY Netz GmbH (Industrietechnik Fröschle)</li>
|
||||
<li><b>EFR</b> - Power meter used by N-ENERGY Netz GmbH</li>
|
||||
<li><b>url</b> - use URL defined via the attributes 'pathString' and 'port'</li>
|
||||
<li><b>file</b> - use file defined via the attribute 'pathString' (positioned in the FHEM file system)</li>
|
||||
The attribute 'pathString' can also be used to add login information to the URL-path of predefined devices.
|
||||
<li><code><deviceType></code>
|
||||
<br>
|
||||
Used to define the path and port to extract the json file.
|
||||
<br>
|
||||
The attribute 'pathString' can be used to add login information to the URL-path of predefined devices.
|
||||
<ul>
|
||||
<li><b>ITF</b> - One tariff electrical meter used by N-ENERGY (Industrietechnik Fröschle)</li>
|
||||
<li><b>EFR</b> - <a href="http://www.efr.de>EFR</a> Smart Grid Hub for electrical meter used by EON, N-ENERGY and EnBW
|
||||
<br>
|
||||
use the 'pathstring' attribute to specifiy your login information
|
||||
<br>
|
||||
<code>attr <device> pathString ?LogName=<i>user</i>&LogPSWD=<i>password</i></code>
|
||||
</li>
|
||||
<li><b>url</b> - use the URL defined via the attributes 'pathString' and 'port'</li>
|
||||
<li><b>file</b> - use the file defined via the attribute 'pathString' (positioned in the FHEM file system)</li>
|
||||
|
||||
</ul>
|
||||
</li>
|
||||
</ul>
|
||||
<br>
|
||||
|
||||
<b>Set</b><br>
|
||||
<ul>
|
||||
@ -579,7 +603,7 @@ JSONMETER_UpdateAborted($)
|
||||
This analysis happens normally only once if readings have been found.</li>
|
||||
</ul>
|
||||
|
||||
<b>Get</b><br>
|
||||
<br>
|
||||
<b>Get</b>
|
||||
<ul>
|
||||
<li><code>jsonFile</code>
|
||||
@ -588,6 +612,7 @@ JSONMETER_UpdateAborted($)
|
||||
</ul>
|
||||
<br>
|
||||
|
||||
<br>
|
||||
<a name="JSONMETERattr"></a>
|
||||
<b>Attributes</b>
|
||||
<ul>
|
||||
@ -596,15 +621,13 @@ JSONMETER_UpdateAborted($)
|
||||
Calculates statistic values - <i>not implemented yet</i></li>
|
||||
<li><code>pathString <string></code>
|
||||
<ul>
|
||||
<li>deviceType 'file': specifies the local file name and path</li>
|
||||
<li>deviceType 'url': specifies the url path</li>
|
||||
<li>other: can be used to add login information to the url path of predefined devices
|
||||
<br>
|
||||
e.g. <code>?LogName=secret&LogPSWD=very_secret</code></li>
|
||||
<li>if deviceType = 'file': specifies the local file name and path</li>
|
||||
<li>if deviceType = 'url': specifies the url path</li>
|
||||
<li>other deviceType: can be used to add login information to the url path of predefined devices</li>
|
||||
</ul>
|
||||
<li><code>port <number></code>
|
||||
<br>
|
||||
if the deviceType 'url' is selected the url port can be specified here (default is 80)</li>
|
||||
Specifies the IP port for the deviceType 'url' (default is 80)</li>
|
||||
<li><a href="#readingFnAttributes">readingFnAttributes</a></li>
|
||||
</ul>
|
||||
</ul>
|
||||
@ -632,16 +655,25 @@ JSONMETER_UpdateAborted($)
|
||||
<br>
|
||||
Bei 0 kann die Geräteabfrage nur manuell gestartet werden.
|
||||
<li><code>Gerätetyp</code>
|
||||
<ul>Definiert den Pfad und den Port, um die JSON-Datei zu einzulesen.
|
||||
<li><b>ITF</b> - Eintarifzähler, genutzt von N-ENERGY Netz GmbH (Industrietechnik Fröschle)</li>
|
||||
<li><b>EFR</b> - Stromzähler, genutzt von N-ENERGY Netz GmbH</li>
|
||||
<br>
|
||||
Definiert den Pfad und den Port, um die JSON-Datei zu einzulesen.
|
||||
<br>
|
||||
Mit dem Attribute 'pathString' können Login Information an den URL-Pfad von vordefinierten Geräte angehangen werden.
|
||||
<ul>
|
||||
<li><b>ITF</b> - Eintarifzähler von N-ENERGY Netz GmbH (Industrietechnik Fröschle)</li>
|
||||
<li><b>EFR</b> - Stromzähler von EON, N-ENERGY, EnBW
|
||||
<br>
|
||||
Die Login Information werden über das Attribute 'pathstring' angegeben.
|
||||
<br>
|
||||
<code>?LogName=<i>Benutzer</i>&LogPSWD=<i>Passwort</i></code></li>
|
||||
<li><b>url</b> - benutzt die URL, welche durch das Attribut 'pathString' und 'port' definiert wird.</li>
|
||||
<li><b>file</b> - benutzt die Datei, welche durch das Attribut 'pathString' definiert wird (im FHEM Dateisystem)</li>
|
||||
Das Attribute 'pathString' kann auch benutzt werdne, um Login Information an den URL-Pfad der vordefinierten Geräte anzuhängen.
|
||||
|
||||
</ul>
|
||||
</li>
|
||||
</ul>
|
||||
|
||||
<br>
|
||||
<b>Set</b><br>
|
||||
<ul>
|
||||
<li><code>INTERVAL <Abfrageinterval></code>
|
||||
@ -657,15 +689,16 @@ JSONMETER_UpdateAborted($)
|
||||
Diese Analysie wird normaler Weise nur einmal durchgeführt, wenn Gerätewerte gefunden wurden.</li>
|
||||
</ul>
|
||||
|
||||
<b>Get</b><br>
|
||||
<br>
|
||||
<b>Get</b>
|
||||
<ul>
|
||||
<li><code>jsonFile</code>
|
||||
<br>
|
||||
Liest die JSON-Datei ein und zeigt sie an</li>
|
||||
Liest die JSON-Datei ein und zeigt sie an.</li>
|
||||
</ul>
|
||||
<br>
|
||||
|
||||
<br>
|
||||
<a name="JSONMETERattr"></a>
|
||||
<b>Attributes</b>
|
||||
<ul>
|
||||
@ -678,11 +711,11 @@ JSONMETER_UpdateAborted($)
|
||||
<li>Gerätetyp 'url': Definiert den URL-Pfad</li>
|
||||
<li>Andere: Kann benutzt werden um Login-Information zum URL Pfad von vordefinerten Geräten hinzuzufügen
|
||||
<br>
|
||||
e.g. <code>?LogName=geheim&LogPSWD=sehr_geheim</code></li>
|
||||
e.g. </li>
|
||||
</ul>
|
||||
<li><code>port <Nummer></code>
|
||||
<br>
|
||||
Beim Gerätetyp 'url' kann hier der URL-Port festgelegt werden (standardmässig 80)</li>
|
||||
Beim Gerätetyp 'url' kann hier der URL-Port festgelegt werden (standardmässig 80)</li>
|
||||
<li><a href="#readingFnAttributes">readingFnAttributes</a></li>
|
||||
</ul>
|
||||
</ul>
|
||||
|