mirror of
https://github.com/fhem/fhem-mirror.git
synced 2025-03-03 16:56:54 +00:00
76_SMAInverter: contrib 2.14.0
git-svn-id: https://svn.fhem.de/fhem/trunk@20334 2b470e98-0d58-463d-a4d8-8e2adae1ed80
This commit is contained in:
parent
f13f6bd0dd
commit
34c4fd1a2d
@ -32,7 +32,7 @@ eval "use FHEM::Meta;1" or my $modMetaAbsent = 1;
|
||||
|
||||
# Versions History by DS_Starter
|
||||
our %SMAInverter_vNotesIntern = (
|
||||
"2.14.0" => "08.10.2019 readings bltotal, bltoday included by 300P",
|
||||
"2.14.0" => "08.10.2019 readings bat_loadtotal (BAT_LOADTOTAL), bat_loadtoday (BAT_LOADTODAY) included by 300P",
|
||||
"2.13.4" => "30.08.2019 STP10.0-3AV-40 298 included into %SMAInverter_devtypes ",
|
||||
"2.13.3" => "28.08.2019 commandref revised ",
|
||||
"2.13.2" => "27.08.2019 fix WARNING: Use of uninitialized value \$_ in substitution (s///) at /opt/fhem//FHEM/Blocking.pm line 238 ",
|
||||
@ -121,8 +121,8 @@ our %SMAInverter_vNotesIntern = (
|
||||
# $inv_TEMP # Inverter temperature
|
||||
# $inv_GRIDRELAY # Grid Relay/Contactor Status
|
||||
# $inv_STATUS # Inverter Status
|
||||
# $inv_SPOT_BATTERYLOAD_TODAY # Today Batteryload
|
||||
# $inv_SPOT_BATTERYLOAD_TOTAL # Total Batteryload
|
||||
# $inv_BAT_LOADTODAY # Today Batteryload
|
||||
# $inv_BAT_LOADTOTAL # Total Batteryload
|
||||
|
||||
# Aufbau Wechselrichter Type-Hash
|
||||
my %SMAInverter_devtypes = (
|
||||
@ -550,7 +550,7 @@ sub SMAInverter_getstatusDoParse($) {
|
||||
$inv_BAT_UDC, $inv_BAT_IDC,
|
||||
$inv_BAT_CYCLES,
|
||||
$inv_BAT_TEMP,
|
||||
$inv_SPOT_BATTERYLOAD_TODAY, $inv_SPOT_BATTERYLOAD_TOTAL,
|
||||
$inv_BAT_LOADTODAY, $inv_BAT_LOADTOTAL,
|
||||
$inv_SPOT_FREQ, $inv_SPOT_OPERTM, $inv_SPOT_FEEDTM, $inv_TEMP, $inv_GRIDRELAY, $inv_STATUS,);
|
||||
|
||||
my @row_array;
|
||||
@ -589,12 +589,12 @@ sub SMAInverter_getstatusDoParse($) {
|
||||
BlockingInformParent("SMAInverter_setReadingFromBlocking", [$name, ".etotal_yesterday", $val], 0);
|
||||
}
|
||||
|
||||
# BATTERYLOAD_TOTAL speichern für BATTERYLOAD_TODAY-Berechnung wenn WR BATTERYLOAD_TODAY nicht liefert
|
||||
# BATTERYLOAD_TOTAL speichern für BAT_LOADTODAY-Berechnung wenn WR BAT_LOADTODAY nicht liefert
|
||||
if ($dt_now >= $oper_stop) {
|
||||
my $val = 0;
|
||||
$val = ReadingsNum($name, "bltotal", 0)*1000 if (exists $defs{$name}{READINGS}{bltotal});
|
||||
$val = ReadingsNum($name, "SPOT_BATTERYLOAD_TOTAL", 0) if (exists $defs{$name}{READINGS}{SPOT_BATTERYLOAD_TOTAL});
|
||||
BlockingInformParent("SMAInverter_setReadingFromBlocking", [$name, ".bltotal_yesterday", $val], 0);
|
||||
$val = ReadingsNum($name, "bat_loadtotal", 0)*1000 if (exists $defs{$name}{READINGS}{bat_loadtotal});
|
||||
$val = ReadingsNum($name, "BAT_LOADTOTAL", 0) if (exists $defs{$name}{READINGS}{BAT_LOADTOTAL});
|
||||
BlockingInformParent("SMAInverter_setReadingFromBlocking", [$name, ".bat_loadtotal_yesterday", $val], 0);
|
||||
}
|
||||
|
||||
if (($oper_start <= $dt_now && $dt_now <= $oper_stop) || AttrVal($name,"suppressSleep",0)) {
|
||||
@ -687,7 +687,7 @@ sub SMAInverter_getstatusDoParse($) {
|
||||
($sup_DeviceStatus,$inv_STATUS,$inv_susyid,$inv_serial) = SMAInverter_SMAcommand($hash, $hash->{HOST}, 0x51800200, 0x00214800, 0x002148FF);
|
||||
}
|
||||
elsif ($i eq "sup_SpotBatteryLoad") {
|
||||
($sup_SpotBatteryLoad,$inv_SPOT_BATTERYLOAD_TODAY,$inv_SPOT_BATTERYLOAD_TOTAL,$inv_susyid,$inv_serial) = SMAInverter_SMAcommand($hash, $hash->{HOST}, 0x54000200, 0x00461F00, 0x00461FFF);
|
||||
($sup_SpotBatteryLoad,$inv_BAT_LOADTODAY,$inv_BAT_LOADTOTAL,$inv_susyid,$inv_serial) = SMAInverter_SMAcommand($hash, $hash->{HOST}, 0x54000200, 0x00461F00, 0x00461FFF);
|
||||
}
|
||||
}
|
||||
|
||||
@ -816,15 +816,15 @@ sub SMAInverter_getstatusDoParse($) {
|
||||
push(@row_array, "bat_idc ".$inv_BAT_IDC."\n");
|
||||
}
|
||||
if($sup_SpotBatteryLoad) {
|
||||
push(@row_array, "bltotal ".($inv_SPOT_BATTERYLOAD_TOTAL/1000)."\n");
|
||||
push(@row_array, "bltoday ".($inv_SPOT_BATTERYLOAD_TODAY/1000)."\n");
|
||||
push(@row_array, "bat_loadtotal ".($inv_BAT_LOADTOTAL/1000)."\n");
|
||||
push(@row_array, "bat_loadtoday ".($inv_BAT_LOADTODAY/1000)."\n");
|
||||
}
|
||||
}
|
||||
|
||||
if($detail_level > 1) {
|
||||
# For Detail Level 2
|
||||
if($sup_BatteryInfo) {
|
||||
push(@row_array,"bat_cycles ".$inv_BAT_CYCLES."\n");
|
||||
push(@row_array, "bat_cycles ".$inv_BAT_CYCLES."\n");
|
||||
push(@row_array, "bat_temp ".$inv_BAT_TEMP."\n");
|
||||
}
|
||||
if($sup_SpotGridFrequency) {
|
||||
@ -911,8 +911,8 @@ sub SMAInverter_getstatusDoParse($) {
|
||||
push(@row_array, "BAT_IDC ".$inv_BAT_IDC."\n");
|
||||
}
|
||||
if($sup_SpotBatteryLoad) {
|
||||
push(@row_array, "SPOT_BATTERYLOAD_TOTAL ".$inv_SPOT_BATTERYLOAD_TOTAL."\n");
|
||||
push(@row_array, "SPOT_BATTERYLOAD_TODAY ".$inv_SPOT_BATTERYLOAD_TODAY."\n");
|
||||
push(@row_array, "BAT_LOADTOTAL ".$inv_BAT_LOADTOTAL."\n");
|
||||
push(@row_array, "BAT_LOADTODAY ".$inv_BAT_LOADTODAY."\n");
|
||||
}
|
||||
}
|
||||
|
||||
@ -1085,7 +1085,7 @@ sub SMAInverter_SMAcommand($$$$$) {
|
||||
$inv_BAT_UDC, $inv_BAT_IDC,
|
||||
$inv_BAT_CYCLES,
|
||||
$inv_BAT_TEMP,
|
||||
$inv_SPOT_BATTERYLOAD_TODAY, $inv_SPOT_BATTERYLOAD_TOTAL,
|
||||
$inv_BAT_LOADTODAY, $inv_BAT_LOADTOTAL,
|
||||
$inv_SPOT_FREQ, $inv_SPOT_OPERTM, $inv_SPOT_FEEDTM, $inv_TEMP, $inv_GRIDRELAY, $inv_STATUS);
|
||||
my $mysusyid = $hash->{HELPER}{MYSUSYID};
|
||||
my $myserialnumber = $hash->{HELPER}{MYSERIALNUMBER};
|
||||
@ -1217,29 +1217,29 @@ sub SMAInverter_SMAcommand($$$$$) {
|
||||
|
||||
if($data_ID eq 0x461F) {
|
||||
if (length($data) >= 66) {
|
||||
$inv_SPOT_BATTERYLOAD_TOTAL = unpack("V*", substr($data, 62, 4));
|
||||
$inv_BAT_LOADTOTAL = unpack("V*", substr($data, 62, 4));
|
||||
} else {
|
||||
Log3 $name, 3, "$name - WARNING - BATTERYLOAD_TOTAL wasn't deliverd ... set it to \"0\" !";
|
||||
$inv_SPOT_ETOTAL = 0;
|
||||
}
|
||||
|
||||
if (length($data) >= 82) {
|
||||
$inv_SPOT_BATTERYLOAD_TODAY = unpack("V*", substr ($data, 78, 4));
|
||||
$inv_BAT_LOADTODAY = unpack("V*", substr ($data, 78, 4));
|
||||
} else {
|
||||
# BATTERYLOAD_TODAY wurde vom WR nicht geliefert, es wird versucht ihn zu berechnen
|
||||
Log3 $name, 3, "$name - BATTERYLOAD_TODAY wasn't delivered from inverter, try to calculate it ...";
|
||||
my $bltotold = ReadingsNum($name, ".bltotal_yesterday", undef);
|
||||
if(defined $bltotold && $inv_SPOT_BATTERYLOAD_TOTAL > $bltotold) {
|
||||
$inv_SPOT_BATTERYLOAD_TODAY = $inv_SPOT_BATTERYLOAD_TOTAL - $bltotold;
|
||||
my $bltotold = ReadingsNum($name, ".bat_loadtotal_yesterday", undef);
|
||||
if(defined $bltotold && $inv_BAT_LOADTOTAL > $bltotold) {
|
||||
$inv_BAT_LOADTODAY = $inv_BAT_LOADTOTAL - $bltotold;
|
||||
Log3 $name, 3, "$name - BATTERYLOAD_TODAY calculated successfully !";
|
||||
} else {
|
||||
Log3 $name, 3, "$name - WARNING - unable to calculate BATTERYLOAD_TODAY ... set it to \"0\" !";
|
||||
$inv_SPOT_BATTERYLOAD_TODAY = 0;
|
||||
$inv_BAT_LOADTODAY = 0;
|
||||
}
|
||||
}
|
||||
|
||||
Log3 $name, 5, "$name - Data SPOT_BATTERYLOAD_TOTAL=$inv_SPOT_BATTERYLOAD_TOTAL and BATTERYLOAD_TODAY=$inv_SPOT_BATTERYLOAD_TODAY";
|
||||
return (1,$inv_SPOT_BATTERYLOAD_TODAY,$inv_SPOT_BATTERYLOAD_TOTAL,$inv_susyid,$inv_serial);
|
||||
Log3 $name, 5, "$name - Data BAT_LOADTOTAL=$inv_BAT_LOADTOTAL and BAT_LOADTODAY=$inv_BAT_LOADTODAY";
|
||||
return (1,$inv_BAT_LOADTODAY,$inv_BAT_LOADTOTAL,$inv_susyid,$inv_serial);
|
||||
}
|
||||
|
||||
if($data_ID eq 0x251E) {
|
||||
@ -1915,8 +1915,8 @@ The retrieval of the inverter will be executed non-blocking. You can adjust the
|
||||
<li><b>BAT_TEMP / bat_temp</b> : Battery temperature </li>
|
||||
<li><b>BAT_UDC / bat_udc</b> : Battery Voltage </li>
|
||||
<li><b>ChargeStatus / chargestatus</b> : Battery Charge status </li>
|
||||
<li><b>SPOT_BATTERYLOAD_TODAY</b> : Battery Load Today </li>
|
||||
<li><b>SPOT_BATTERYLOAD_TOTAL</b> : Battery Load Total </li>
|
||||
<li><b>BAT_LOADTODAY</b> : Battery Load Today </li>
|
||||
<li><b>BAT_LOADTOTAL</b> : Battery Load Total </li>
|
||||
<li><b>ChargeStatus / chargestatus</b> : Battery Charge status </li>
|
||||
<li><b>CLASS / device_class</b> : Inverter Class </li>
|
||||
<li><b>PACMAX1 / pac_max_phase_1</b> : Nominal power in Ok Mode </li>
|
||||
@ -2149,8 +2149,8 @@ Die Abfrage des Wechselrichters wird non-blocking ausgeführt. Der Timeoutwert f
|
||||
<li><b>BAT_TEMP / bat_temp</b> : Akku Temperatur </li>
|
||||
<li><b>BAT_UDC / bat_udc</b> : Akku Spannung </li>
|
||||
<li><b>ChargeStatus / chargestatus</b> : Akku Ladestand </li>
|
||||
<li><b>SPOT_BATTERYLOAD_TODAY</b> : Battery Load Today </li>
|
||||
<li><b>SPOT_BATTERYLOAD_TOTAL</b> : Battery Load Total </li>
|
||||
<li><b>BAT_LOADTODAY</b> : Battery Load Today </li>
|
||||
<li><b>BAT_LOADTOTAL</b> : Battery Load Total </li>
|
||||
<li><b>CLASS / device_class</b> : Wechselrichter Klasse </li>
|
||||
<li><b>PACMAX1 / pac_max_phase_1</b> : Nominelle Leistung in Ok Mode </li>
|
||||
<li><b>PACMAX1_2 / pac_max_phase_1_2</b> : Maximale Leistung (für einige Wechselrichtertypen) </li>
|
||||
|
Loading…
x
Reference in New Issue
Block a user