LUXTRONIK: Replaced with set hotWaterCircPumpDeaerate on|off

git-svn-id: https://svn.fhem.de/fhem/trunk@9156 2b470e98-0d58-463d-a4d8-8e2adae1ed80
This commit is contained in:
tpoitzsch 2015-08-29 15:24:26 +00:00
parent 9438a0eee1
commit 3377d1d25b

View File

@ -307,21 +307,21 @@ LUXTRONIK2_Set($$@)
$hash->{LOCAL} = 0; $hash->{LOCAL} = 0;
return $resultStr; return $resultStr;
} }
elsif( int(@_)==4 && $cmd eq 'hotWaterCircPumpExtern' ) { # Einstellung->Entlüftung elsif( int(@_)==4 && $cmd eq 'hotWaterCircPumpDeaerate' ) { # Einstellung->Entlüftung
Log3 $name, 3, "LUXTRONIK2: set $name $cmd $val"; Log3 $name, 3, "LUXTRONIK2: set $name $cmd $val";
return "$name Error: Wrong parameter given for opModeHotWater, use Automatik,Party,Off" return "$name Error: Wrong parameter given for opModeHotWater, use Automatik,Party,Off"
if $val !~ /on|off/; if $val !~ /on|off/;
$hash->{LOCAL} = 1; $hash->{LOCAL} = 1;
$resultStr = LUXTRONIK2_SetParameter ($hash, $cmd, $val); $resultStr = LUXTRONIK2_SetParameter ($hash, $cmd, $val);
if ($val eq "on" ) { $resultStr .= LUXTRONIK2_SetParameter ($hash, "confirmDegasing", 1); } if ($val eq "on" ) { $resultStr .= LUXTRONIK2_SetParameter ($hash, "runDeaerate", 1); }
else { $resultStr .= LUXTRONIK2_SetParameter ($hash, "confirmDegasing", 0); } # only send if no degasing checkbox is selected at all. else { $resultStr .= LUXTRONIK2_SetParameter ($hash, "runDeaerate", 0); } # only send if no Deaerate checkbox is selected at all.
$hash->{LOCAL} = 0; $hash->{LOCAL} = 0;
return $resultStr; return $resultStr;
} }
my $list = "statusRequest:noArg" my $list = "statusRequest:noArg"
." activeTariff:0,1,2,3,4,5,6,7,8,9" ." activeTariff:0,1,2,3,4,5,6,7,8,9"
." hotWaterCircPumpExtern:on,off" ." hotWaterCircPumpDeaerate:on,off"
." hotWaterTemperatureTarget " ." hotWaterTemperatureTarget "
." resetStatistics:all,statBoilerGradientCoolDownMin,statAmbientTemp...,statElectricity...,statHours...,statHeatQ..." ." resetStatistics:all,statBoilerGradientCoolDownMin,statAmbientTemp...,statElectricity...,statHours...,statHeatQ..."
." returnTemperatureSetBack " ." returnTemperatureSetBack "
@ -1135,11 +1135,11 @@ LUXTRONIK2_SetParameter($$$)
$realValue = $setValue / 10; $realValue = $setValue / 10;
} }
elsif ($parameterName eq "hotWaterCircPumpExtern") { #isVisible(167) elsif ($parameterName eq "hotWaterCircPumpDeaerate") { #isVisible(167)
$setParameter = 684; $setParameter = 684;
$setValue = $realValue eq "on" ? 1 : 0; $setValue = $realValue eq "on" ? 1 : 0;
} }
elsif ($parameterName eq "confirmDegasing") { elsif ($parameterName eq "runDeaerate") {
$setParameter = 158; $setParameter = 158;
$setValue = $realValue; $setValue = $realValue;
} }
@ -1191,7 +1191,7 @@ LUXTRONIK2_SetParameter($$$)
$socket->close(); $socket->close();
readingsSingleUpdate($hash,$parameterName,$realValue,1) unless $parameterName eq "confirmDegasing"; readingsSingleUpdate($hash,$parameterName,$realValue,1) unless $parameterName eq "runDeaerate";
return undef; return undef;
} }
@ -1802,8 +1802,10 @@ LUXTRONIK2_doStatisticDeltaSingle ($$$$$$$)
<li><code>hotWaterTemperatureTarget &lt;temperature&gt;</code><br> <li><code>hotWaterTemperatureTarget &lt;temperature&gt;</code><br>
Target temperature of domestic hot water boiler in &deg;C Target temperature of domestic hot water boiler in &deg;C
</li><br> </li><br>
<li><code>hotWaterCirculationPumpExtern &lt;on | off&gt;</code><br> <li><code>hotWaterCircPumpDeaerate &lt;on | off&gt;</code><br>
Switches the external circulation pump for the hot water on or off. The circulation prevents a cool down of the hot water in the pipes but increases the heat consumption drastically. Switches the external circulation pump for the hot water on or off. The circulation prevents a cool down of the hot water in the pipes but increases the heat consumption drastically.
<br>
NOTE! It uses the deaerate function of the controller. So, the pump alternates always 5 minutes on and 5 minutes off.
</li><br> </li><br>
<li><code>opModeHotWater &lt;Mode&gt;</code><br> <li><code>opModeHotWater &lt;Mode&gt;</code><br>
Operating Mode of domestic hot water boiler (Auto | Party | Off) Operating Mode of domestic hot water boiler (Auto | Party | Off)
@ -1921,8 +1923,10 @@ LUXTRONIK2_doStatisticDeltaSingle ($$$$$$$)
Dieser Wert muss entsprechend des vorhandenen oder geplanten Tarifes zum jeweiligen Zeitpunkt z.B. durch den FHEM-Befehl "at" gesetzt werden.<br> Dieser Wert muss entsprechend des vorhandenen oder geplanten Tarifes zum jeweiligen Zeitpunkt z.B. durch den FHEM-Befehl "at" gesetzt werden.<br>
0 = tariflos 0 = tariflos
</li><br> </li><br>
<li><code>hotWaterCirculationPumpExtern &lt;on | off&gt;</code><br> <li><code>hotWaterCircPumpDeaerate &lt;on | off&gt;</code><br>
Schaltet die externe Warmwasser-Zirkulationspumpe an oder aus. Durch die Zirkulation wird ein Abk&uuml;hlen des Warmwassers in den Hausleitungen verhindert. Der W&auml;rmeverbrauch steigt jedoch drastisch. Schaltet die externe Warmwasser-Zirkulationspumpe an oder aus. Durch die Zirkulation wird das Abk&uuml;hlen des Warmwassers in den Hausleitungen verhindert. Der W&auml;rmeverbrauch steigt jedoch drastisch.
<br>
Achtung! Es wird die Entl&uuml;ftungsfunktion der Steuerung genutzt. Dadurch taktet die Pumpe jeweils 5 Minuten ein und 5 Minuten aus.
</li><br> </li><br>
<li><code>hotWaterTemperatureTarget &lt;Temperatur&gt;</code> <li><code>hotWaterTemperatureTarget &lt;Temperatur&gt;</code>