From 31d1cc9e8f41ce3261c746a8cbd87329fe38700c Mon Sep 17 00:00:00 2001 From: tpoitzsch <> Date: Sun, 29 Apr 2012 09:43:57 +0000 Subject: [PATCH] Heizungsmodus: Sommerbetrieb git-svn-id: https://svn.fhem.de/fhem/trunk@1502 2b470e98-0d58-463d-a4d8-8e2adae1ed80 --- fhem/contrib/23_LUXTRONIK2.pm | 8 +++++++- 1 file changed, 7 insertions(+), 1 deletion(-) diff --git a/fhem/contrib/23_LUXTRONIK2.pm b/fhem/contrib/23_LUXTRONIK2.pm index 4dac683c2..982c55d4b 100644 --- a/fhem/contrib/23_LUXTRONIK2.pm +++ b/fhem/contrib/23_LUXTRONIK2.pm @@ -190,7 +190,13 @@ LUXTRONIK2_GetStatus($) $sensor = "hotWaterOperatingMode"; $switch = $heatpump_parameters[4]; - if ($switch==0) { $value = "Automatik"; } + if ($switch==0) { + if($heatpump_values[16]>=$heatpump_parameters[700] && $heatpump_parameters[699]==1) { + $value = "Automatik - Sommerbetrieb (Aus)"; + } else { + $value = "Automatik"; + } + } elsif ($switch==1) { $value = "Zusatzheizung"; } elsif ($switch==2) { $value = "Party"; } elsif ($switch==3) { $value = "Ferien"; }