mirror of
https://github.com/fhem/fhem-mirror.git
synced 2025-04-08 13:24:56 +00:00
THZ: new firmware 2.14j for joerg old tecalor
git-svn-id: https://svn.fhem.de/fhem/trunk@26174 2b470e98-0d58-463d-a4d8-8e2adae1ed80
This commit is contained in:
parent
3c6f60b3c8
commit
30714e0772
@ -2,7 +2,7 @@
|
||||
# 00_THZ
|
||||
# $Id$
|
||||
# by immi 06/2022
|
||||
my $thzversion = "0.204";
|
||||
my $thzversion = "0.205";
|
||||
# this code is based on the hard work of Robert; I just tried to port it
|
||||
# http://robert.penz.name/heat-pump-lwz/
|
||||
########################################################################################
|
||||
@ -246,12 +246,33 @@ my %parsinghash = (
|
||||
[" heatTemp: ", 28, 4, "hex2int", 10],
|
||||
[" seasonMode: ", 38, 2, "somwinmode", 1],
|
||||
[" integralSwitch: ", 44, 4, "hex2int", 1], [" hcOpMode: ", 48, 2, "opmodehc", 1],
|
||||
[" roomSetTemp: ", 62, 4, "hex2int", 10], [" x60: ", 60, 4, "hex2int", 10],
|
||||
[" roomSetTemp: ", 62, 4, "hex2int", 10], [" x60: ", 60, 4, "hex2int", 10],
|
||||
[" x64: ", 64, 4, "raw", 1], [" insideTempRC: ", 68, 4, "hex2int", 10],
|
||||
[" x72: ", 72, 4, "raw", 1], [" x76: ", 76, 4, "raw", 1],
|
||||
[" onHysteresisNo: ", 32, 2, "hex", 1], [" offHysteresisNo: ", 34, 2, "hex", 1],
|
||||
[" hcBoosterStage: ", 36, 2, "hex", 1]
|
||||
],
|
||||
# contribution from joerg hellijo Antwort #1085 Juni 2022
|
||||
"F4hc1214j" => [["outsideTemp: ", 4, 4, "hex2int", 10], [" x08: ", 8, 4, "raw", 1],
|
||||
[" returnTemp: ", 12, 4, "hex2int", 10], [" integralHeat: ", 16, 4, "hex2int", 1],
|
||||
[" flowTemp: ", 20, 4, "hex2int", 10], [" heatSetTemp: ", 24, 4, "hex2int", 10],
|
||||
[" heatTemp: ", 28, 4, "hex2int", 10],
|
||||
[" seasonMode: ", 38, 2, "somwinmode", 1],
|
||||
[" integralSwitch: ", 44, 4, "hex2int", 1], [" hcOpMode: ", 48, 2, "opmodehc", 1],
|
||||
[" roomSetTemp: ", 62, 4, "hex2int", 10], [" x50: ", 50, 4, "hex2int", 10],
|
||||
[" x66: ", 66, 4, "raw", 1], [" insideTempRC: ", 74, 4, "hex2int", 10],
|
||||
[" x70: ", 70, 4, "raw", 1], [" x76: ", 78, 4, "raw", 1],
|
||||
[" onHysteresisNo: ", 32, 2, "hex", 1], [" offHysteresisNo: ", 34, 2, "hex", 1],
|
||||
[" hcStage: ", 36, 2, "hex", 1],# 0=Aus; 1=Solar; 2=V1
|
||||
[" boosterStage2: ", 40, 1, "bit3", 1],
|
||||
[" x58: ", 58, 4, "raw", 1], [" x54: ", 54, 4, "raw", 1],
|
||||
[" blockTimeAfterCompStart: ", 82, 4, "hex2int", 1], [" insideTemp: ", 86, 4, "hex2int", 10],
|
||||
[" solarPump: ", 40, 1, "bit2", 1], [" boosterStage1: ", 40, 1, "bit1", 1],
|
||||
[" compressor: ", 40, 1, "bit0", 1], [" heatPipeValve: ", 41, 1, "bit3", 1],
|
||||
[" diverterValve: ", 41, 1, "bit2", 1], [" dhwPump: ", 41, 1, "bit1", 1],
|
||||
[" heatingCircuitPump: ", 41, 1, "bit0", 1], [" mixerOpen: ", 43, 1, "bit1", 1],
|
||||
[" mixerClosed: ", 43, 1, "bit0", 1]
|
||||
],
|
||||
"F5hc2" => [["outsideTemp: ", 4, 4, "hex2int", 10], [" returnTemp: ", 8, 4, "hex2int", 10],
|
||||
[" vorlaufTemp: ", 12, 4, "hex2int", 10], [" heatSetTemp: ", 16, 4, "hex2int", 10],
|
||||
[" heatTemp: ", 20, 4, "hex2int", 10], [" stellgroesse: ", 24, 4, "hex2int", 10],
|
||||
@ -845,6 +866,18 @@ my %getsonly214 = (
|
||||
"sGlobal" => {cmd2=>"FB", type =>"FBglob214",unit =>""}
|
||||
);
|
||||
|
||||
my %getsonly214j = ( # contribution from joerg hellijo Antwort #1085 Juni 2022
|
||||
"pFan" => {cmd2=>"01", type =>"01pxx214", unit =>""},
|
||||
"pExpert" => {cmd2=>"02", type =>"02pxx206", unit =>""},
|
||||
"sControl" => {cmd2=>"F2", type =>"F2type", unit =>""},
|
||||
"sHC1" => {cmd2=>"F4", type =>"F4hc1214j", unit =>""},
|
||||
#"sLVR" => {cmd2=>"E8", type =>"E8tyype", unit =>""},
|
||||
#"sF0" => {cmd2=>"F0", type =>"F0type", unit =>""},
|
||||
#"sF1" => {cmd2=>"F1", type =>"F1type", unit =>""},
|
||||
#"sEF" => {cmd2=>"EF", type =>"EFtype", unit =>""},
|
||||
"sGlobal" => {cmd2=>"FB", type =>"FBglob214",unit =>""}
|
||||
);
|
||||
|
||||
|
||||
my %sets= (%sets439539common, %sets439only);
|
||||
my %gets= (%getsonly439, %sets);
|
||||
@ -906,7 +939,7 @@ sub THZ_Initialize($) {
|
||||
."interval_sBoostHCTotal:0,3600,7200,28800,43200,86400 "
|
||||
."interval_sFlowRate:0,3600,7200,28800,43200,86400 "
|
||||
."interval_sDisplay:0,60,120,180,300 "
|
||||
."firmware:4.39,2.06,2.14,5.39,4.39technician "
|
||||
."firmware:4.39,2.06,2.14,2.14j,5.39,4.39technician "
|
||||
."interval_sDewPointHC1:0,60,120,180,300 "
|
||||
."simpleReadTimeout:0.25,0.5,0.75,1,2,4,6 " #standard has been 0.75 since msg468515 If blocking attribut is NOT enabled then set the timeout value to a maximum value of 0.75 sec.
|
||||
."nonblocking:0,1 "
|
||||
@ -1963,6 +1996,10 @@ sub THZ_Attr(@) {
|
||||
%sets = (%sets206, %setsonly214);
|
||||
%gets = (%getsonly2xx, %getsonly214, %sets206);
|
||||
}
|
||||
elsif ($attrVal eq "2.14j") {
|
||||
%sets = (%sets206, %setsonly214);
|
||||
%gets = (%getsonly2xx, %getsonly214j, %sets206);
|
||||
}
|
||||
elsif ($attrVal eq "5.39") {
|
||||
%sets=(%sets439539common, %sets539only);
|
||||
%gets=(%getsonly539, %sets);
|
||||
|