commandref: documentation for event-aggregator added

git-svn-id: https://svn.fhem.de/fhem/trunk@7718 2b470e98-0d58-463d-a4d8-8e2adae1ed80
This commit is contained in:
borisneubert 2015-01-25 17:37:12 +00:00
parent 6cba6e4fbe
commit 2c6f024ead
2 changed files with 102 additions and 1 deletions

View File

@ -450,6 +450,7 @@ attribute list if you want to know if a device supports these attributes. <br>
this attribute is enclused in {}, then it is evaluated. This attribute is
evaluated each time a reading is updated.
</li>
<p>
<a name="event-on-update-reading"></a>
<li>event-on-update-reading<br>
@ -459,7 +460,8 @@ attribute list if you want to know if a device supports these attributes. <br>
expressions in that list. If set, only updates of the listed readings
create events.
</li>
<p>
<a name="event-on-change-reading"></a>
<li>event-on-change-reading<br>
The attribute takes a comma-separated list of readings. You may use regular
@ -479,6 +481,56 @@ attribute list if you want to know if a device supports these attributes. <br>
reading creates an event no matter whether the reading is also listed
in event-on-change-reading.</li>
</ol>
<p>
<a name="event-aggregator"></a>
<li>event-aggregator</li>
The primary uses of this attribute are to calculate (time-weighted) averages of
readings over time periods and to throttle the update rate of readings and thus
the amount of data written to the logs.<p>
This attribute takes a comma-separated list of <code>reading:interval:method:function</code>
quadruples. You may use regular expressions for <code>reading</code>. If set, updates for the
listed readings are ignored and associated events are suppressed for a black-out period of at
least <code>interval</code> seconds. After the black-out period has expired, the reading is
updated with a value that is calculated from the values and timestamps of the previously ignored
updates within the black-out period as follows:
<table>
<tr><th>function</th><th>description</th></tr>
<tr><td>v</td><td>the last value encountered</td></tr>
<tr><td>v0</td><td>the first value encountered</td></tr>
<tr><td>min</td><td>the smallest value encountered</td></tr>
<tr><td>max</td><td>the largest value encountered</td></tr>
<tr><td>mean</td><td>the arithmetic mean of all values</td></tr>
<tr><td>sd</td><td>the standard deviation from the mean</td></tr>
</table>
<p>
If <code>method</code> is <code>none</code>, then that's all there is. If <code>method</code>
is <code>const</code> or <code>linear</code>, the time-weighted series of values is taken into
account instead. The weight is the timespan between two subsequent updates.
With the <code>const</code> method, the value is the value of the reading at the beginning of
the timespan; with the <code>linear</code> method, the value is the arithmetic average of
the values at the beginning and the end of the timespan.
Rollovers of black-out periods are handled as one would expect it.<p>
One would typically use the <code>linear</code> method with the <code>mean</code> function for
quantities continuously varying over time like electric power consumption, temperature or speed.
For cumulative quantities like energy consumed, rain fallen or distance covered,
the <code>none</code> method with the <code>v</code> function is used. The <code>constant</code>
method is for discrete quantities that stay constant until the corresponding reading is updated,
e.g. counters, switches and the like.<p>
The event aggregator only takes into consideration those updates that remain after preprocessing
according to the <code>event-on-update-reading</code> and <code>event-on-change-reading</code>
directives. Besides which, any update of a reading that occurs within a timespan from the preceding
update that is smaller than the resolution of FHEM's time granularity is ditched.<p>
Example:<br>
<code>attr myPowerMeter event-aggregator EP_POWER_METER:300:linear:mean,EP_ENERGY_METER:300:none:v</code>
</li>
<p>
<a name="event-min-interval"></a>
<li>event-min-interval<br>
@ -487,6 +539,7 @@ attribute list if you want to know if a device supports these attributes. <br>
generated, if at least minInterval seconds elapsed since the last reading
of the matched type.
</li>
<p>
<a name="userReadings"></a>
<li>userReadings<br>

View File

@ -505,6 +505,54 @@ Ger&auml;t dokumentiert.
"reading" auch in event-on-change-reading aufgelistet ist.</li>
</ol>
<a name="event-aggregator"></a>
<li>event-aggregator</li>
The primary uses of this attribute are to calculate (time-weighted) averages of
readings over time periods and to throttle the update rate of readings and thus
the amount of data written to the logs.<p>
This attribute takes a comma-separated list of <code>reading:interval:method:function</code>
quadruples. You may use regular expressions for <code>reading</code>. If set, updates for the
listed readings are ignored and associated events are suppressed for a black-out period of at
least <code>interval</code> seconds. After the black-out period has expired, the reading is
updated with a value that is calculated from the values and timestamps of the previously ignored
updates within the black-out period as follows:
<table>
<tr><th>function</th><th>description</th></tr>
<tr><td>v</td><td>the last value encountered</td></tr>
<tr><td>v0</td><td>the first value encountered</td></tr>
<tr><td>min</td><td>the smallest value encountered</td></tr>
<tr><td>max</td><td>the largest value encountered</td></tr>
<tr><td>mean</td><td>the arithmetic mean of all values</td></tr>
<tr><td>sd</td><td>the standard deviation from the mean</td></tr>
</table>
<p>
If <code>method</code> is <code>none</code>, then that's all there is. If <code>method</code>
is <code>const</code> or <code>linear</code>, the time-weighted series of values is taken into
account instead. The weight is the timespan between two subsequent updates.
With the <code>const</code> method, the value is the value of the reading at the beginning of
the timespan; with the <code>linear</code> method, the value is the arithmetic average of
the values at the beginning and the end of the timespan.
Rollovers of black-out periods are handled as one would expect it.<p>
One would typically use the <code>linear</code> method with the <code>mean</code> function for
quantities continuously varying over time like electric power consumption, temperature or speed.
For cumulative quantities like energy consumed, rain fallen or distance covered,
the <code>none</code> method with the <code>v</code> function is used. The <code>constant</code>
method is for discrete quantities that stay constant until the corresponding reading is updated,
e.g. counters, switches and the like.<p>
The event aggregator only takes into consideration those updates that remain after preprocessing
according to the <code>event-on-update-reading</code> and <code>event-on-change-reading</code>
directives. Besides which, any update of a reading that occurs within a timespan from the preceding
update that is smaller than the resolution of FHEM's time granularity is ditched.<p>
Example:<br>
<code>attr myPowerMeter event-aggregator EP_POWER_METER:300:linear:mean,EP_ENERGY_METER:300:none:v</code>
</li>
<a name="event-min-interval"></a>
<li>event-min-interval<br>
Dieses Attribut enth&auml;lt eine durch Kommata getrennte Liste von