@ -2206,6 +2206,12 @@ LUXTRONIK2_doStatisticDeltaSingle ($$$$$$$)
|
||||
<li><code>INTERVAL <polling interval></code><br>
|
||||
Polling interval in seconds
|
||||
</li><br>
|
||||
<li><code>heatingCurveEndPoint <Temperarature></code><br>
|
||||
Sets the heating curve parameter. Adjustable in 0.1 steps.
|
||||
</li><br>
|
||||
<li><code>heatingCurveOffset <Temperarature></code><br>
|
||||
Sets the heating curve parameter. Adjustable in 0.1 steps.
|
||||
</li><br>
|
||||
<li><code>hotWaterTemperatureTarget <temperature></code><br>
|
||||
Target temperature of domestic hot water boiler in °C
|
||||
</li><br>
|
||||
@ -2223,7 +2229,7 @@ LUXTRONIK2_doStatisticDeltaSingle ($$$$$$$)
|
||||
</li><br>
|
||||
<li><code>returnTemperatureHyst <Temperature></code>
|
||||
<br>
|
||||
Hysteresis of the returnTemperatureTarget of the heating controller . 0.5 K till 3 K. Adjustable in 0.1 steps.
|
||||
Hysteresis of the returnTemperatureTarget of the heating controller. 0.5 K till 3 K. Adjustable in 0.1 steps.
|
||||
</li><br>
|
||||
<li><code>returnTemperatureSetBack <Temperature></code>
|
||||
<br>
|
||||
@ -2239,9 +2245,19 @@ LUXTRONIK2_doStatisticDeltaSingle ($$$$$$$)
|
||||
|
||||
<a name="LUXTRONIK2get"></a>
|
||||
<b>Get</b>
|
||||
<ul>
|
||||
No get implemented yet ...
|
||||
</ul>
|
||||
<ul>
|
||||
<li><code>heatingCurveParameter <OutsideTemp1 SetTemp1 OutsideTemp2 SetTemp2></code>
|
||||
<br>
|
||||
Determines based on two points on the heating curve the respective heat curve parameter <i>heatingCurveEndPoint</i> and <i>heatingCurveOffset</i>.<br>
|
||||
These parameter can be set via the respective set commands.
|
||||
</li>
|
||||
<br>
|
||||
<li><code>rawData</code>
|
||||
<br>
|
||||
Shows a table with all parameter and operational values returned by the controller.<br>
|
||||
They can be assigned to device readings via the attributes <i>userHeatpumpParameters</i> und <i>userHeatpumpValues</i>.
|
||||
</li><br>
|
||||
</ul>
|
||||
<br>
|
||||
|
||||
<a name="LUXTRONIK2attr"></a>
|
||||
@ -2289,6 +2305,17 @@ LUXTRONIK2_doStatisticDeltaSingle ($$$$$$$)
|
||||
<br>
|
||||
Currently, if the value of this attribute is not NULL, the corresponding reading consists of the current status of the heat pump and the temperature of the water.
|
||||
</li><br>
|
||||
<li><code>userHeatpumpParameters <Index [Name][,Index2 [Name2],Index3 [Name3] ...]></code>
|
||||
<br>
|
||||
Allows to continuousely read the value of certian controler parameters. The index number of the parameter can be determined with the get command <i>rawData</i><br>
|
||||
In the attribute definition, a name can be writen behind the index number separated by a space. The respective parameter value will either be shown with the prefix "userParameter..." or under the given name. <br>
|
||||
Multiple indexes are separated by a comma.<br>
|
||||
If the readings are not used anymore the can be deleted with the FHEM command <a href="#deletereading">deleteReading</a>.
|
||||
</li><br>
|
||||
<li><code>userHeatpumpValues <Index Name[,Index2 Name2,Index3 Name3 ...]></code>
|
||||
<br>
|
||||
Allows to read out specific operational values. Proceed as with <i>userHeatpumpParameters</i>.
|
||||
</li><br>
|
||||
<li><a href="#readingFnAttributes">readingFnAttributes</a></li>
|
||||
</ul>
|
||||
</ul>
|
||||
@ -2336,6 +2363,12 @@ LUXTRONIK2_doStatisticDeltaSingle ($$$$$$$)
|
||||
Dieser Wert muss entsprechend des vorhandenen oder geplanten Tarifes zum jeweiligen Zeitpunkt z.B. durch den FHEM-Befehl "at" gesetzt werden.<br>
|
||||
0 = tariflos
|
||||
</li><br>
|
||||
<li><code>heatingCurveEndPoint <Temperaratur></code><br>
|
||||
Einstellung des Heizkurvenparameters. In 0.1er Schritten einstellbar.
|
||||
</li><br>
|
||||
<li><code>heatingCurveOffset <Temperaratur></code><br>
|
||||
Einstellung des Heizkurvenparameters. In 0.1er Schritten einstellbar.
|
||||
</li><br>
|
||||
<li><code>hotWaterCircPumpDeaerate <on | off></code><br>
|
||||
Schaltet die externe Warmwasser-Zirkulationspumpe an oder aus. Durch die Zirkulation wird das Abkühlen des Warmwassers in den Hausleitungen verhindert. Der Wärmeverbrauch steigt jedoch drastisch.
|
||||
<br>
|
||||
@ -2378,10 +2411,16 @@ LUXTRONIK2_doStatisticDeltaSingle ($$$$$$$)
|
||||
<a name="LUXTRONIK2get"></a>
|
||||
<b>Get</b>
|
||||
<ul>
|
||||
<li><code>heatingCurveParameter <Aussentemp1 Solltemp1 Aussentemp2 Solltemp2></code>
|
||||
<br>
|
||||
Ermittelt rekursiv anhand zweier Punkte auf der Heizkurve die entsprechenden Heizkurvenparameter <i>heatingCurveEndPoint</i> und <i>heatingCurveOffset</i>.<br>
|
||||
Diese können dann über die entsprechenden set-Befehl einstellt werden.
|
||||
</li>
|
||||
<br>
|
||||
<li><code>rawData</code>
|
||||
<br>
|
||||
Zeigt alle von der Steuerung auslesbaren Parameter und Betriebswerte an.<br>
|
||||
Diese können dann mit den Attributen "userHeatpumpParameters" und "userHeatpumpValues" einem Gerätewert zugeordnet werden.
|
||||
Diese können dann mit den Attributen <i>userHeatpumpParameters</i> und <i>userHeatpumpValues</i> einem Gerätewert zugeordnet werden.
|
||||
</li><br>
|
||||
</ul>
|
||||
<br>
|
||||
@ -2441,14 +2480,14 @@ LUXTRONIK2_doStatisticDeltaSingle ($$$$$$$)
|
||||
</li><br>
|
||||
<li><code>userHeatpumpParameters <Index [Name][,Index2 [Name2],Index3 [Name3] ...]></code>
|
||||
<br>
|
||||
Erlaubt das Auslesen der Werte benutzerspezifischer Parameter. Die Indizes der verf¨gbaren Parameterwerte können mit dem get-Befehl "rawData" ermittelt werden.<br>
|
||||
Der jeweilige Index-Wert wird entweder als "user"-Gerätewert oder unter dem angegebenen Namen angezeigt. In der Attributdefinition kann der Name hinter den Index getrennt durch ein Leerzeichen geschrieben werden.<br>
|
||||
Erlaubt das Auslesen der Werte benutzerspezifischer Parameter. Die Indizes der verf¨gbaren Parameterwerte können mit dem get-Befehl <i>rawData</i> ermittelt werden.<br>
|
||||
In der Attributdefinition kann der Name hinter den Index getrennt durch ein Leerzeichen geschrieben werden. Der jeweilige Parameter-Wert wird entweder mit dem Präfix "userParameter..." oder unter dem angegebenen Namen angezeigt. <br>
|
||||
Mehrere Indizes werden durch Kommas getrennt.<br>
|
||||
Nicht mehr benötigte Gerätewerte können mit dem FHEM-Befehl <a href="#deletereading">deleteReading</a> gelöscht werden.
|
||||
Nicht mehr benötigte Gerätewerte können mit dem FHEM-Befehl <a href="#deletereading">deleteReading</a> gelöscht werden.
|
||||
</li><br>
|
||||
<li><code>userHeatpumpValues <Index Name[,Index2 Name2,Index3 Name3 ...]></code>
|
||||
<br>
|
||||
Erlaubt das Auslesen benutzerspezifische Betriebswerte. Vorgehen wie bei userHeatpumpParameters
|
||||
Erlaubt das Auslesen benutzerspezifische Betriebswerte. Vorgehen wie bei <i>userHeatpumpParameters</i>.
|
||||
</li><br>
|
||||
<li><a href="#readingFnAttributes">readingFnAttributes</a>
|
||||