mirror of
https://github.com/fhem/fhem-mirror.git
synced 2025-03-03 10:46:53 +00:00
luxtronik2, statistics: bug fixes
git-svn-id: https://svn.fhem.de/fhem/trunk@6799 2b470e98-0d58-463d-a4d8-8e2adae1ed80
This commit is contained in:
parent
e429465583
commit
27acaa8b74
@ -1,4 +1,4 @@
|
||||
###############################################################
|
||||
###############################################################
|
||||
# $Id$
|
||||
#
|
||||
# 23_LUXTRONIK2.pm
|
||||
@ -767,18 +767,19 @@ LUXTRONIK2_UpdateDone($)
|
||||
#WM[kW] = delta_Temp [K] * Durchfluss [l/h] / ( 3.600 [kJ/kWh] / ( 4,179 [kJ/(kg*K)] (H2O Wärmekapazität bei 30 & 40°C) * 0,994 [kg/l] (H2O Dichte bei 35°C) )
|
||||
my $thermalPower = 0;
|
||||
# 0=Heizen, 5=Brauchwasser, 7=Abtauen, 16=Durchflussüberwachung
|
||||
if ($a[3] =~ /^(0|5|16)$/ ) {
|
||||
$thermalPower = abs($flowTemperature - $returnTemperature) * $a[19] / 866.65;
|
||||
if ($a[3] =~ /^(0|5|16)$/) {
|
||||
if ($a[19] !~ /no/) { $thermalPower = abs($flowTemperature - $returnTemperature) * $a[19] / 866.65; } #Nur bei Wärmezählern
|
||||
$heatPumpPower = AttrVal($name, "heatPumpElectricalPowerWatt", -1);
|
||||
$heatPumpPower *= (1 + ($flowTemperature-35) * AttrVal($name, "heatPumpElectricalPowerFactor", 0));
|
||||
}
|
||||
readingsBulkUpdate( $hash, "thermalPower", sprintf "%.1f", $thermalPower);
|
||||
if ($a[19] !~ /no/) { readingsBulkUpdate( $hash, "thermalPower", sprintf "%.1f", $thermalPower); } #Nur bei Wärmezählern
|
||||
if ($heatPumpPower >-1 ) { readingsBulkUpdate( $hash, "heatPumpElectricalPowerEstimated", sprintf "%.0f", $heatPumpPower); }
|
||||
if ($heatPumpPower > 0) {
|
||||
if ($heatPumpPower > 0 && $a[19] !~ /no/) { #Nur bei Wärmezählern
|
||||
$cop = $thermalPower * 1000 / $heatPumpPower;
|
||||
readingsBulkUpdate( $hash, "COP", sprintf "%.2f", $cop);
|
||||
}
|
||||
|
||||
|
||||
# if selected, do all the statistic calculations
|
||||
if ( $doStatistic == 1) {
|
||||
#LUXTRONIK2_doStatisticBoilerHeatUp $hash, $currOpHours, $currHQ, $currTemp, $opState, $target
|
||||
@ -805,13 +806,13 @@ LUXTRONIK2_UpdateDone($)
|
||||
Log3 $name,3,"$name: statBoilerGradientCoolDownMin set to '$value'";
|
||||
}
|
||||
}
|
||||
|
||||
# LUXTRONIK2_doStatisticThermalPower: $hash, $MonitoredOpState, $currOpState, $currHeatQuantity, $currOpHours, $currAmbTemp, $currHeatSourceIn, $TargetTemp, $electricalPower
|
||||
|
||||
# LUXTRONIK2_doStatisticThermalPower: $hash, $MonitoredOpState, $currOpState, $currHeatQuantity, $currOpHours, $currAmbTemp, $currHeatSourceIn, $TargetTemp, $electricalPower
|
||||
$value = LUXTRONIK2_doStatisticThermalPower ($hash, 5, $a[3], $a[37]/10, $a[35], $ambientTemperature, $heatSourceIN,$hotWaterTemperatureTarget, $heatPumpPower);
|
||||
if ($value ne "") { readingsBulkUpdate($hash,"statThermalPowerBoiler",$value); }
|
||||
$value = LUXTRONIK2_doStatisticThermalPower ($hash, 0, $a[3], $a[36]/10, $a[34], $ambientTemperature, $heatSourceIN, $returnTemperatureTarget, $heatPumpPower);
|
||||
if ($value ne "") { readingsBulkUpdate($hash,"statThermalPowerHeating",$value); }
|
||||
|
||||
|
||||
# LUXTRONIK2_doStatisticMinMax $hash, $readingName, $value
|
||||
LUXTRONIK2_doStatisticMinMax ( $hash, "statAmbientTemp", $ambientTemperature);
|
||||
|
||||
@ -1725,7 +1726,7 @@ LUXTRONIK2_doStatisticDeltaSingle ($$$$$$$)
|
||||
<br>
|
||||
It has a built-in ethernet port, so it can be directly integrated into a local area network (LAN).
|
||||
<br>
|
||||
<i>The modul is reported to work with firmware: V1.51, V1.54C, V1.60, V1.69, V1.70.</i>
|
||||
<i>The modul is reported to work with firmware: V1.51, V1.54C, V1.60, V1.64, V1.69, V1.70.</i>
|
||||
<br>
|
||||
More Info on the particular <a href="http://www.fhemwiki.de/wiki/Luxtronik_2.0">page of FHEM-Wiki</a> (in German).
|
||||
<br>
|
||||
@ -1843,7 +1844,7 @@ LUXTRONIK2_doStatisticDeltaSingle ($$$$$$$)
|
||||
Siemens Novelan (WPR NET) und Wolf Heiztechnik (BWL/BWS) verbaut ist.
|
||||
Sie besitzt einen Ethernet Anschluss, so dass sie direkt in lokale Netzwerke (LAN) integriert werden kann.
|
||||
<br>
|
||||
<i>Das Modul wurde bisher mit folgender Steuerungs-Firmware getestet: V1.51, V1.54C, V1.60, V1.69, V1.70.</i>
|
||||
<i>Das Modul wurde bisher mit folgender Steuerungs-Firmware getestet: V1.51, V1.54C, V1.60, V1.64, V1.69, V1.70.</i>
|
||||
<br>
|
||||
Mehr Infos im entsprechenden <u><a href="http://www.fhemwiki.de/wiki/Luxtronik_2.0">Artikel der FHEM-Wiki</a></u>.
|
||||
<br>
|
||||
|
@ -969,8 +969,8 @@ statistics_FormatDuration($)
|
||||
sub ########################################
|
||||
statistics_maxDecPlaces($$)
|
||||
{
|
||||
my ($value,$decMax) = @_;
|
||||
$decMax = 0 if $decMax == undef;
|
||||
my ($value, $decMax) = @_;
|
||||
$decMax = 0 if ! defined $decMax;
|
||||
if ( $value =~ /.*\.(.*)/ ) {
|
||||
my $decPlaces = length($1);
|
||||
$decMax = $decPlaces >= $decMax ? $decPlaces : $decMax;
|
||||
|