- change: 76_SolarForecast: optimize battery management once more
|
||||
- feature: 00_KNXIO: set-cmds: connect, disconnect, restart
|
||||
- feature: 76_SolarForecast: Consumer planning can now react dynamically to
|
||||
changing or time-shifting PV generation,
|
||||
|
@ -157,6 +157,7 @@ BEGIN {
|
||||
|
||||
# Versions History intern
|
||||
my %vNotesIntern = (
|
||||
"1.7.1" => "20.01.2024 optimize battery management ",
|
||||
"1.7.0" => "18.01.2024 Changeover Start centralTask completely to runCentralTask, ".
|
||||
"aiAddRawData: Weekday from pvHistory not taken into account greater than current day ".
|
||||
"__reviewSwitchTime: new function for review consumer planning state ".
|
||||
@ -6358,7 +6359,7 @@ sub _batSocTarget {
|
||||
delete $paref->{careCycle};
|
||||
|
||||
my $nt;
|
||||
my $chargereq = 0; # Ladeanforedrung wenn SoC unter Minimum SoC gefallen ist
|
||||
my $chargereq = 0; # Ladeanforderung wenn SoC unter Minimum SoC gefallen ist
|
||||
my $target = $lowSoc;
|
||||
my $yday = strftime "%d", localtime($t - 86400); # Vortag (range 01 to 31)
|
||||
my $batymaxsoc = HistoryVal ($hash, $yday, 99, 'batmaxsoc', 0); # gespeicherter max. SOC des Vortages
|
||||
@ -6368,7 +6369,7 @@ sub _batSocTarget {
|
||||
$batymaxsoc >= $maxsoc ? $batysetsoc - $batSocChgDay :
|
||||
$batysetsoc; # neuer Min SOC für den laufenden Tag
|
||||
|
||||
debugLog ($paref, 'batteryManagement', "SoC calc Step1 - compare with SoC history -> Target: $target %");
|
||||
debugLog ($paref, 'batteryManagement', "SoC calc Step1 - compare with SoC history -> new Target: $target %");
|
||||
|
||||
## Pflege-SoC (Soll SoC $maxSoCdef bei $batSocChgDay % Steigerung p. Tag)
|
||||
###########################################################################
|
||||
@ -6403,21 +6404,19 @@ sub _batSocTarget {
|
||||
my $pvexpect = $pvfctm > $pvfctd ? $pvfctm : $pvfctd;
|
||||
|
||||
my $batinstcap = CurrentVal ($hash, 'batinstcap', 0); # installierte Batteriekapazität Wh
|
||||
my $needcharge = $batinstcap - ($batinstcap / 100 * $batcharge); # vorläufige benötigte Ladeenergie (Wh) bis 100% SOC
|
||||
my $cancharge = $pvexpect > $needcharge ? $pvexpect : $needcharge; # resultierende benötigte Ladeenergie (Wh)
|
||||
my $cantarget = 100 - (100 / $batinstcap) * $cancharge; # berechneter möglicher Min SOC nach Berücksichtigung Ladewahrscheinlichkeit
|
||||
my $cantarget = 100 - (100 / $batinstcap) * $pvexpect; # berechneter möglicher Min SOC nach Berücksichtigung Ladewahrscheinlichkeit
|
||||
|
||||
my $newtarget = sprintf "%.0f", ($cantarget < $target ? $cantarget : $target); # Abgleich möglicher Min SOC gg. berechneten Min SOC
|
||||
my $logadd = '';
|
||||
|
||||
if ($newtarget > $csopt && $t > $delayts) { # Erhöhung des SoC erst ab Sonnenuntergang anwenden
|
||||
if ($newtarget > $csopt && $t > $delayts) { # Erhöhung des SoC (wird ab Sonnenuntergang angewendet)
|
||||
$target = $newtarget;
|
||||
$logadd = "(new target > $csopt % and Sunset has passed)";
|
||||
}
|
||||
elsif ($newtarget > $csopt && $t <= $delayts) { # bisheriges Optimum bleibt vorerst
|
||||
$target = $csopt;
|
||||
$nt = (timestampToTimestring ($delayts, $paref->{lang}))[0];
|
||||
$logadd = "(new target $newtarget % is only activated after $nt)";
|
||||
$logadd = "(calculated new target $newtarget % is only activated after $nt)";
|
||||
}
|
||||
elsif ($newtarget < $csopt) { # Targetminderung sofort umsetzen -> Freiplatz für Ladeprognose
|
||||
$target = $newtarget;
|
||||
@ -6454,7 +6453,7 @@ sub _batSocTarget {
|
||||
}
|
||||
|
||||
debugLog ($paref, 'batteryManagement', "SoC calc Step6 - force charging request: ".
|
||||
($chargereq ? 'yes (battery charge is below minimum SoC)' : 'no (sufficient battery charge)'));
|
||||
($chargereq ? 'yes (battery charge is below minimum SoC)' : 'no (Battery is sufficiently charged)'));
|
||||
|
||||
## pvHistory/Readings schreiben
|
||||
#################################
|
||||
@ -16448,6 +16447,8 @@ to ensure that the system configuration is correct.
|
||||
<a id="SolarForecast-attr-affectMaxDayVariance"></a>
|
||||
<li><b>affectMaxDayVariance <Zahl> </b><br>
|
||||
Maximum change size of the PV prediction factor (Reading pvCorrectionFactor_XX) per day. <br>
|
||||
This setting has no influence on the learning and forecasting behavior of any AI support used
|
||||
(<a href="#SolarForecast-set-pvCorrectionFactor_Auto">pvCorrectionFactor_Auto</a>). <br>
|
||||
(default: 0.5)
|
||||
</li>
|
||||
<br>
|
||||
@ -18485,6 +18486,9 @@ die ordnungsgemäße Anlagenkonfiguration geprüft werden.
|
||||
<a id="SolarForecast-attr-affectMaxDayVariance"></a>
|
||||
<li><b>affectMaxDayVariance <Zahl> </b><br>
|
||||
Maximale Änderungsgröße des PV Vorhersagefaktors (Reading pvCorrectionFactor_XX) pro Tag. <br>
|
||||
Auf das Lern- und Prognoseverhalten einer eventuell verwendeten KI-Unterstützung
|
||||
(<a href="#SolarForecast-set-pvCorrectionFactor_Auto">pvCorrectionFactor_Auto</a>) hat diese Einstellung keinen
|
||||
Einfluß. <br>
|
||||
(default: 0.5)
|
||||