From 2154665b59dff883592fd67f9850dd83b5d1f2f0 Mon Sep 17 00:00:00 2001
From: tpoitzsch <>
Date: Wed, 12 Mar 2014 18:17:26 +0000
Subject: [PATCH] LUXTRONIK2: min/max and cumulative statistics
git-svn-id: https://svn.fhem.de/fhem/trunk@5206 2b470e98-0d58-463d-a4d8-8e2adae1ed80
---
fhem/FHEM/23_LUXTRONIK2.pm | 603 +++++++++++++++++++++++++++++--------
1 file changed, 471 insertions(+), 132 deletions(-)
diff --git a/fhem/FHEM/23_LUXTRONIK2.pm b/fhem/FHEM/23_LUXTRONIK2.pm
index 6f23de325..117379a21 100644
--- a/fhem/FHEM/23_LUXTRONIK2.pm
+++ b/fhem/FHEM/23_LUXTRONIK2.pm
@@ -39,13 +39,19 @@ use IO::Socket;
use Time::HiRes qw/ time /;
use Net::Telnet;
+sub LUXTRONIK2_doStatisticThermalPower ($$$$$$$);
+sub LUXTRONIK2_doStatisticMinMax ($$$);
+sub LUXTRONIK2_doStatisticMinMaxSingle ($$$$);
+sub LUXTRONIK2_storeReadings ($$$$$);
+sub LUXTRONIK2_doStatisticDelta ($$$$) ;
+
# Modul Version for remote debugging
- my $modulVersion = "2014-02-20";
+ my $modulVersion = "2014-03-03";
#List of firmware versions that are known to be compatible with this modul
my $testedFirmware = "#V1.54C#V1.60#V1.69#";
my $compatibleFirmware = "#V1.54C#V1.60#V1.69#";
-
+
sub ########################################
LUXTRONIK2_Initialize($)
{
@@ -59,10 +65,11 @@ LUXTRONIK2_Initialize($)
$hash->{AttrList} = "disable:0,1 ".
"allowSetParameter:0,1 ".
"autoSynchClock:slider,10,5,300 ".
+ "boilerVolumn ".
"doStatistics:0,1 ".
"ignoreFirmwareCheck:0,1 ".
"statusHTML ".
- $readingFnAttributes;
+ $readingFnAttributes;
}
sub ########################################
@@ -151,6 +158,7 @@ LUXTRONIK2_Notify(@) {
hotWaterState => "opStateHotWater",
heatingSystemCirculationPump => "heatingSystemCircPump",
hotWaterCirculationPumpExtern => "hotWaterCircPumpExtern",
+ currentThermalOutput => "thermalPower",
statGradientBoilerTempLoss => "statBoilerGradientHeatUp' and 'statBoilerGradientCoolDown" );
my $oldReading;
my $newReading;
@@ -192,31 +200,40 @@ LUXTRONIK2_Set($$@)
my ($hash, $name, $cmd, $val) = @_;
my $resultStr = "";
- if($cmd eq 'statusRequest') {
- $hash->{LOCAL} = 1;
- LUXTRONIK2_GetUpdate($hash);
- $hash->{LOCAL} = 0;
- return undef;
- }
- elsif ($cmd eq 'resetStatistics') {
- if ( ($val eq "all" || $val eq "statBoilerGradientCoolDownMin")
- && exists($defs{$name}{READINGS}{statBoilerGradientCoolDownMin})) {
- delete $defs{$name}{READINGS}{statBoilerGradientCoolDownMin};
- $resultStr .= " statBoilerGradientCoolDownMin";
+ if($cmd eq 'statusRequest') {
+ $hash->{LOCAL} = 1;
+ LUXTRONIK2_GetUpdate($hash);
+ $hash->{LOCAL} = 0;
+ return undef;
}
- if ( $resultStr eq "" ) {
- $resultStr = "$name: No statistics to reset";
- } else {
- $resultStr = "$name: Statistic value(s) deleted:" . $resultStr;
+ elsif ($cmd eq 'resetStatistics') {
+ if ( $val eq "statBoilerGradientCoolDownMin"
+ && exists($hash->{READINGS}{statBoilerGradientCoolDownMin})) {
+ delete $hash->{READINGS}{statBoilerGradientCoolDownMin};
+ $resultStr .= " statBoilerGradientCoolDownMin";
+ }
+ elsif ($val eq 'all') {
+ foreach (sort keys %{ $hash->{READINGS} }) {
+ if ($_ =~ /^\.?stat/ && $_ ne "state") {
+ delete $hash->{READINGS}{$_};
+ $resultStr .= " " . $_;
+ }
+ }
+ }
+ if ( $resultStr eq "" ) {
+ $resultStr = "$name: No statistics to reset";
+ } else {
+ $resultStr = "$name: Statistic value(s) deleted:" . $resultStr;
+ WriteStatefile();
+ }
+ # Log3 $hash, 3, $resultStr;
+ return $resultStr;
+ }
+ elsif($cmd eq 'INTERVAL' && int(@_)==4 ) {
+ $val = 30 if( $val < 30 );
+ $hash->{INTERVAL}=$val;
+ return "Polling interval set to $val seconds.";
}
- Log3 $hash, 3, $resultStr;
- return $resultStr;
- }
- elsif($cmd eq 'INTERVAL' && int(@_)==4 ) {
- $val = 30 if( $val < 30 );
- $hash->{INTERVAL}=$val;
- return "Polling interval set to $val seconds.";
- }
#Check Firmware and Set-Paramter-lock
if ($cmd eq 'synchronizeClockHeatPump' ||
@@ -256,12 +273,13 @@ LUXTRONIK2_Set($$@)
return $resultStr;
}
- my $list = "statusRequest:noArg".
- " resetStatistics:all,statBoilerGradientCoolDownMin".
- " hotWaterTemperatureTarget:slider,30.0,0.5,65.0".
- " opModeHotWater:Auto,Party,Off".
- " synchronizeClockHeatPump:noArg".
- " INTERVAL:slider,30,30,1800";
+ my $list = "statusRequest:noArg"
+ ." resetStatistics:all,statBoilerGradientCoolDownMin"
+ ." hotWaterTemperatureTarget:slider,30.0,0.5,65.0"
+ ." opModeHotWater:Auto,Party,Off"
+ ." synchronizeClockHeatPump:noArg"
+ ." INTERVAL:slider,30,30,1800";
+
return "Unknown argument $cmd, choose one of $list";
}
@@ -443,9 +461,9 @@ LUXTRONIK2_DoUpdate($)
#(FVA) read next 4 bytes of response -> should be number_of_Visibility_Attributes > 0
$socket->recv($result,4);
- $count = unpack("N", $result);
- if($count == 0) {
- Log3 $name, 2, "$name LUXTRONIK2_DoUpdate-Error: 0 visibility attributes announced: ".length($result)." -> ".$count;
+ my $countVisibAttr = unpack("N", $result);
+ if($countVisibAttr == 0) {
+ Log3 $name, 2, "$name LUXTRONIK2_DoUpdate-Error: 0 visibility attributes announced: ".length($result)." -> ".$countVisibAttr;
$socket->close();
return "$name|0|0 visibility attributes announced";
}
@@ -454,25 +472,25 @@ LUXTRONIK2_DoUpdate($)
$i=1;
$result="";
$buf="";
- while($i<=$count) {
+ while($i<=$countVisibAttr) {
$socket->recv($buf,1);
$result.=$buf;
$i++;
}
- if(length($result) != $count) {
- Log3 $name, 1, "$name LUXTRONIK2_DoUpdate-Error: Visibility attributes length check: ".length($result)." should have been ". $count;
+ if(length($result) != $countVisibAttr) {
+ Log3 $name, 1, "$name LUXTRONIK2_DoUpdate-Error: Visibility attributes length check: ".length($result)." should have been ". $countVisibAttr;
$socket->close();
return "$name|0|Number of Visibility attributes read mismatch ( $!)\n";
}
- @heatpump_visibility = unpack("C$count", $result);
- if(scalar(@heatpump_visibility) != $count) {
- Log3 $name, 2, "$name LUXTRONIK2_DoUpdate-Error: Unpacking problem by visibility attributes: ".scalar(@heatpump_visibility)." instead of ".$count;
+ @heatpump_visibility = unpack("C$countVisibAttr", $result);
+ if(scalar(@heatpump_visibility) != $countVisibAttr) {
+ Log3 $name, 2, "$name LUXTRONIK2_DoUpdate-Error: Unpacking problem by visibility attributes: ".scalar(@heatpump_visibility)." instead of ".$countVisibAttr;
$socket->close();
return "$name|0|Unpacking problem of visibility attributes";
}
- Log3 $name, 5, "$name: $count visibility attributs received";
+ Log3 $name, 5, "$name: $countVisibAttr visibility attributs received";
####################################
@@ -560,7 +578,7 @@ LUXTRONIK2_DoUpdate($)
$return_str .= "|". ($heatpump_visibility[196]==1 ? $heatpump_values[65] : "no");
# 36 - counterHeatQHeating
$return_str .= "|" . $heatpump_values[151];
- # 37 - counterHeatQHeating
+ # 37 - counterHeatQHotWater
$return_str .= "|". $heatpump_values[152];
# 38 - counterHours2ndHeatSource2
$return_str .= "|". ($heatpump_visibility[85]==1 ? $heatpump_values[61] : "no");
@@ -592,7 +610,8 @@ LUXTRONIK2_DoUpdate($)
$return_str .= "|". ($heatpump_visibility[37]==1 ? $heatpump_values[27] : "no");
# 52 - counterHoursSolar
$return_str .= "|". ($heatpump_visibility[248]==1 ? $heatpump_values[161] : "no");
-
+ # 53 - Number of visibility attributes
+ $return_str .= "|".$countVisibAttr;
return $return_str;
}
@@ -676,6 +695,8 @@ LUXTRONIK2_UpdateDone($)
my $counterRetry = $hash->{fhem}{counterRetry};
$counterRetry++;
+ my $doStatistic = AttrVal($name,"doStatistics",0);
+
if ($a[1]==0 ) {
readingsSingleUpdate($hash,"state","Error: ".$a[2],1);
$counterRetry = 0;
@@ -700,19 +721,21 @@ LUXTRONIK2_UpdateDone($)
my $hotWaterTemperature = LUXTRONIK2_CalcTemp($a[14]);
my $hotWaterTemperatureTarget = LUXTRONIK2_CalcTemp($a[25]);
my $hotWaterTemperatureThreshold = LUXTRONIK2_CalcTemp($a[25] - $a[49]);
- my $thresholdHeatingLimit = LUXTRONIK2_CalcTemp($a[21]);
+ my $heatSourceIN = LUXTRONIK2_CalcTemp($a[23]);
+ my $thresholdHeatingLimit = LUXTRONIK2_CalcTemp($a[21]);
my $thresholdTemperatureSetBack = LUXTRONIK2_CalcTemp($a[48]);
my $flowTemperature = LUXTRONIK2_CalcTemp($a[15]);
my $returnTemperature = LUXTRONIK2_CalcTemp($a[16]);
# if selected, do all the statistic calculations
- if ( AttrVal($name,"doStatistics",0) == 1) {
+ if ( $doStatistic == 1) {
#LUXTRONIK2_doStatisticBoilerHeatUp $hash, $currOpHours, $currHQ, $currTemp, $opState, $target
$value = LUXTRONIK2_doStatisticBoilerHeatUp ($hash, $a[35], $a[37]/10, $hotWaterTemperature, $a[3],$hotWaterTemperatureTarget);
if ($value ne "") {
readingsBulkUpdate($hash,"statBoilerGradientHeatUp",$value);
Log3 $name,3,"$name: statBoilerGradientHeatUp set to $value";
}
+
#LUXTRONIK2_doStatisticBoilerCoolDown $hash, $time, $currTemp, $opState, $target, $threshold
$value = LUXTRONIK2_doStatisticBoilerCoolDown ($hash, $a[22], $hotWaterTemperature, $a[3], $hotWaterTemperatureTarget, $hotWaterTemperatureThreshold);
if ($value ne "") {
@@ -730,8 +753,18 @@ LUXTRONIK2_UpdateDone($)
Log3 $name,3,"$name: statBoilerGradientCoolDownMin set to $value";
}
}
- }
+
+ # LUXTRONIK2_doStatisticThermalPower: $hash, $MonitoredOpState, $currOpState, $currHeatQuantity, $currOpHours, $currAmbTemp, $currHeatSourceIn
+ $value = LUXTRONIK2_doStatisticThermalPower ($hash, 5, $a[3], $a[37]/10, $a[35], $ambientTemperature, $heatSourceIN);
+ if ($value ne "") { readingsBulkUpdate($hash,"statThermalPowerBoiler",$value); }
+ $value = LUXTRONIK2_doStatisticThermalPower ($hash, 0, $a[3], $a[36]/10, $a[34], $ambientTemperature, $heatSourceIN);
+ if ($value ne "") { readingsBulkUpdate($hash,"statThermalPowerHeating",$value); }
+ # LUXTRONIK2_doStatisticMinMax $hash, $readingName, $value
+ LUXTRONIK2_doStatisticMinMax ( $hash, "statAmbientTemp", $ambientTemperature);
+
+ }
+
#Operating status of heat pump
my $opStateHeatPump1 = $wpOpStat1{$a[2]}; ##############
$opStateHeatPump1 = "unbekannt (".$a[2].")" unless $opStateHeatPump1;
@@ -824,10 +857,22 @@ LUXTRONIK2_UpdateDone($)
readingsBulkUpdate( $hash, "returnTemperatureTarget",LUXTRONIK2_CalcTemp($a[17]));
if ($a[18] !~ /no/) {readingsBulkUpdate( $hash, "returnTemperatureExtern",LUXTRONIK2_CalcTemp($a[18]))};
readingsBulkUpdate( $hash, "flowRate",$a[19]);
- readingsBulkUpdate( $hash, "heatSourceIN",LUXTRONIK2_CalcTemp($a[23]));
+ readingsBulkUpdate( $hash, "heatSourceIN",$heatSourceIN);
readingsBulkUpdate( $hash, "heatSourceOUT",LUXTRONIK2_CalcTemp($a[24]));
readingsBulkUpdate( $hash, "hotGasTemperature",LUXTRONIK2_CalcTemp($a[26]));
+ # Operating hours (seconds->hours) and heat quantities
+ # LUXTRONIK2_storeReadings: $hash, $readingName, $value, $factor, $doStatistic
+ LUXTRONIK2_storeReadings $hash, "counterHours2ndHeatSource1", $a[32], 3600, $doStatistic;
+ LUXTRONIK2_storeReadings $hash, "counterHours2ndHeatSource2", $a[38], 3600, $doStatistic;
+ LUXTRONIK2_storeReadings $hash, "counterHours2ndHeatSource3", $a[39], 3600, $doStatistic;
+ LUXTRONIK2_storeReadings $hash, "counterHoursHeatPump", $a[33], 3600, $doStatistic;
+ LUXTRONIK2_storeReadings $hash, "counterHoursHeating", $a[34], 3600, $doStatistic;
+ LUXTRONIK2_storeReadings $hash, "counterHoursHotWater", $a[35], 3600, $doStatistic;
+ LUXTRONIK2_storeReadings $hash, "counterHeatQHeating", $a[36], 10, $doStatistic;
+ LUXTRONIK2_storeReadings $hash, "counterHeatQHotWater", $a[37], 10, $doStatistic;
+ LUXTRONIK2_storeReadings $hash, "counterHeatQTotal", $a[36] + $a[37], 10, $doStatistic;
+
# Input / Output status
readingsBulkUpdate($hash,"heatingSystemCircPump",$a[27]?"on":"off");
@@ -852,41 +897,36 @@ LUXTRONIK2_UpdateDone($)
$value = "unbekannt (".$a[31].")" unless $value;
readingsBulkUpdate($hash,"typeHeatpump",$value);
- # Operating hours (seconds->hours) and heat quantities, write/create readings only if >0
- if ($a[32] !~ /no/) {readingsBulkUpdate($hash,"counterHours2ndHeatSource1", sprintf("%.1f", $a[32]/3600));}
- if ($a[38] !~ /no/) {readingsBulkUpdate($hash,"counterHours2ndHeatSource2", sprintf("%.1f", $a[38]/3600));}
- if ($a[39] !~ /no/) {readingsBulkUpdate($hash,"counterHours2ndHeatSource3", sprintf("%.1f", $a[39]/3600));}
- if ($a[33] !~ /no/) {readingsBulkUpdate($hash,"counterHoursHeatPump", sprintf("%.1f", $a[33]/3600));}
- if ($a[34] !~ /no/) {readingsBulkUpdate($hash,"counterHoursHeating", sprintf("%.1f", $a[34]/3600));}
- if ($a[35] !~ /no/) {readingsBulkUpdate($hash,"counterHoursHotWater", sprintf("%.1f", $a[35]/3600));}
- if ($a[36] > 0) {readingsBulkUpdate($hash,"counterHeatQHeating", $a[36]/10);}
- if ($a[37] > 0) {readingsBulkUpdate($hash,"counterHeatQHotWater" ,$a[37]/10);}
- if ($a[36] > 0 && $a[37] > 0) {readingsBulkUpdate($hash,"counterHeatQTotal",($a[36]+$a[37])/10);}
#WM[kW] = delta_Temp [K] * Durchfluss [l/h] / ( 3.600 [kJ/kWh] / ( 4,179 [kJ/(kg*K)] (H2O Wärmekapazität bei 30 & 40°C) * 0,994 [kg/l] (H2O Dichte bei 35°C) )
- $value = ($flowTemperature-$returnTemperature) * $a[19] / 866.65;
- readingsBulkUpdate( $hash, "currentThermalOutput", sprintf("%.1f", $value));
-
- # Solar
+ my $thermalPower = 0;
+ # 0=Heizen, 5=Brauchwasser, 7=Abtauen, 16=Durchflussüberwachung
+ if ($a[3] =~ /^(0|5|16)$/ ) { $thermalPower = sprintf "%.1f", abs($flowTemperature - $returnTemperature) * $a[19] / 866.65; }
+ readingsBulkUpdate( $hash, "thermalPower", $thermalPower);
+
+ # Solar
if ($a[50] !~ /no/) {readingsBulkUpdate($hash, "solarCollectorTemperature", LUXTRONIK2_CalcTemp($a[50]));}
if ($a[51] !~ /no/) {readingsBulkUpdate($hash, "solarBufferTemperature", LUXTRONIK2_CalcTemp($a[51]));}
if ($a[52] !~ /no/) {readingsBulkUpdate($hash, "counterHoursSolar", sprintf("%.1f", $a[52]/3600));}
# HTML for floorplan
if(AttrVal($name, "statusHTML", "none") ne "none") {
- $value = "
" . $a[0] . "
";
- $value .= "$opStateHeatPump1
";
- $value .= "$opStateHeatPump2
";
- $value .= "$opStateHeatPump3
";
+ $value = ""; #"" . $a[0] . "
\n";
+ $value .= "$opStateHeatPump1
\n";
+ $value .= "$opStateHeatPump2
\n";
+ $value .= "$opStateHeatPump3
\n";
$value .= "Brauchwasser: $hotWaterTemperature °C";
readingsBulkUpdate($hash,"floorplanHTML",$value);
}
# State update
- readingsBulkUpdate($hash,"state","$opStateHeatPump1 $opStateHeatPump2 - $opStateHeatPump3");
+ $value = "$opStateHeatPump1 $opStateHeatPump2 - $opStateHeatPump3";
+ if ($thermalPower != 0) { $value .= " ($thermalPower kW)"; }
+ readingsBulkUpdate($hash, "state", $value);
readingsEndUpdate($hash,1);
$hash->{helper}{fetched_calc_values} = $a[44];
$hash->{helper}{fetched_parameters} = $a[45];
+ $hash->{helper}{fetched_visib_attr} = $a[53];
############################
#Auto Synchronize Device Clock
@@ -921,7 +961,6 @@ LUXTRONIK2_UpdateDone($)
}
-
sub ########################################
LUXTRONIK2_UpdateAborted($)
{
@@ -1072,7 +1111,7 @@ LUXTRONIK2_synchronizeClock (@)
Log3 $name, 5, "$name: Read current time of host";
my @output = $telnet->cmd('date +%s');
- $delay = floor(time()) - $output[0];
+ $delay = sprintf("%.1f",time() - $output[0]);
Log3 $name, 5, "$name: Current time is ".localtime($output[0])." Delay is $delay seconds.";
if (abs($delay)>$maxDelta && $maxDelta!=0) {
@@ -1110,21 +1149,60 @@ LUXTRONIK2_checkFirmware ($)
}
}
+# Calculate heat-up gradients of boiler based on hotWaterTemperature and counterHeatQHeating
+sub ########################################
+LUXTRONIK2_doStatisticThermalPower ($$$$$$$)
+{
+ my ($hash, $MonitoredOpState, $currOpState, $currHeatQuantity, $currOpHours, $currAmbTemp, $currHeatSourceIn) = @_;
+ my @last = split / /, $hash->{fhem}{"statThermalPowerOpState_".$MonitoredOpState} || "1";
+ my $saveCurrent = 0;
+ my $returnStr = "";
+ my $value1;
+ my $value2;
+ my $value3;
+
+ if ($last[0] != $MonitoredOpState && $currOpState == $MonitoredOpState ) {
+ $saveCurrent = 1;
+ } elsif ($last[0] == $MonitoredOpState && $currOpState != $MonitoredOpState && $currOpState != 16 ) { #16=Durchflussüberwachung
+ $saveCurrent = 1;
+ $value2 = ($currOpHours - $last[2])/60;
+ if ($value2 > 9.5) {
+ $value1 = ($currAmbTemp + $last[3]) / 2;
+ $returnStr = "aT: " . sprintf "%.1f", $value1;
+ $value1 = $currHeatQuantity - $last[1];
+ $value3 = $value1 * 60 / $value2;
+ $returnStr .= " thP: " . sprintf "%.1f", $value3;
+ $returnStr .= " t: " . sprintf "%.0f", $value2;
+ $returnStr .= " DQ: " . sprintf "%.1f", $value1;
+ $value1 = ($currHeatSourceIn + $last[4]) / 2;
+ $returnStr .= " iT: " . sprintf "%.1f", $value1;
+ }
+ }
+ if ($saveCurrent == 1) {
+ $last[0] = $currOpState;
+ $last[1] = $currHeatQuantity;
+ $last[2] = $currOpHours;
+ $last[3] = $currAmbTemp;
+ $last[4] = $currHeatSourceIn;
+ $hash->{fhem}{"statThermalPowerOpState_".$MonitoredOpState} = join( " ", @last);
+ }
+ return $returnStr;
+}
+
# Calculate heat-up gradients of boiler based on hotWaterTemperature and counterHeatQHeating
sub ########################################
LUXTRONIK2_doStatisticBoilerHeatUp ($$$$$$)
{
-
- my ($hash, $currOpHours, $currHQ, $currTemp, $opState, $target) = @_;
+ my ($hash, $currOpHours, $currHQ, $currTemp, $opState, $target) = @_;
my $name = $hash->{NAME};
- my $step = $hash->{fhem}{statBoilerHeatUpStep};
+ my $step = $hash->{fhem}{statBoilerHeatUpStep};
my $minTemp = $hash->{fhem}{statBoilerHeatUpMin};
my $maxTemp = $hash->{fhem}{statBoilerHeatUpMax};
my $lastHQ = $hash->{fhem}{statBoilerHeatUpHQ};
my $lastOpHours = $hash->{fhem}{statBoilerHeatUpOpHours};
my $value1 = 0;
- my $value2 = 0;
- my $value3 = 0;
+ my $value2 = 0;
+ my $value3 = 0;
my $returnStr = "";
# step 0 = Initialize - if hot water preparation is off
@@ -1191,18 +1269,22 @@ LUXTRONIK2_doStatisticBoilerHeatUp ($$$$$$)
Log3 $name, 4, "$name: Statistic Boiler Heat-Up step 3->1: Boiler heat-up measurement finished";
$value1 = ( int(10 * $maxTemp) - int(10 * $minTemp) ) / 10; # delta hot water temperature
$value2 = ( $currOpHours - $lastOpHours ) / 60; # delta time (minutes)
- # $value3 = floor(100 * $value1 / $value2 + 0.5) / 100; # Temperature gradient over time rounded to 1/100th
- # $value2 = floor(100 * $value2 + 0.5) / 100; # rounded to 1/100th
$returnStr = "DT/min: ".sprintf("%.2f", $value1/$value2)." DT: ".sprintf("%.2f", $value1)." Dmin: ".sprintf("%.0f", $value2);
- $value2 = $currHQ - $lastHQ; # delta heat quantity
- # $value2 = floor(10*($currHQ - $lastHQ)+0.5)/10; # delta heat quantity
- # $value3 = floor(100 * $value2 / $value1 + 0.5) / 100; # heat gradient over temperature rounded to 1/100th
- $returnStr .= " DQ/T: ".sprintf("%.2f",$value2/$value1)." DQ: ".sprintf("%.1f",$value2);
-
- #Volumen [l] = Wärmemenge [kWh] / (delta T) [K] * ( 3.600 [kJ/kWh] / ( 4,179 [kJ/(kg*K)] (H2O Wärmekapazität bei 40°C) * 0,992 [kg/l] (H2O Dichte bei 40°C) ) [K/(kWh*l)] )
- $value3 = 868.4 * $value2 / $value1 ; # heated water volume in liter
- $returnStr .= " DV: ".sprintf("%.0f",$value3);
+ $value3 = $currHQ - $lastHQ; # delta heat quantity
+ # Delta Heat Quantity
+ $returnStr .= " DQ: ".sprintf("%.1f",$value3);
+ # Average thermal power
+ $returnStr .= " thP: ".sprintf("%.1f",$value3 * 60 / $value2);
+
+
+ #real (mixed) Temperature-Difference
+ my $boilerVolumn = AttrVal($name, "boilerVolumn", 0);
+ if ($boilerVolumn >0 ) {
+ # (delta T) [K] = Wärmemenge [kWh] / #Volumen [l] * ( 3.600 [kJ/kWh] / ( 4,179 [kJ/(kg*K)] (H2O Wärmekapazität bei 40°C) * 0,992 [kg/l] (H2O Dichte bei 40°C) ) [K/(kWh*l)] )
+ $value2 = 868.4 * $value3 / $boilerVolumn ;
+ $returnStr .= " realDT: ".sprintf("%.0f", $value2);
+ }
$step = 1;
$lastOpHours = $currOpHours;
@@ -1211,8 +1293,8 @@ LUXTRONIK2_doStatisticBoilerHeatUp ($$$$$$)
}
}
- $hash->{fhem}{statBoilerHeatUpStep} = $step;
- $hash->{fhem}{statBoilerHeatUpMin} = $minTemp;
+ $hash->{fhem}{statBoilerHeatUpStep} = $step;
+ $hash->{fhem}{statBoilerHeatUpMin} = $minTemp;
$hash->{fhem}{statBoilerHeatUpMax} = $maxTemp;
$hash->{fhem}{statBoilerHeatUpHQ} = $lastHQ;
$hash->{fhem}{statBoilerHeatUpOpHours} = $lastOpHours;
@@ -1225,18 +1307,20 @@ LUXTRONIK2_doStatisticBoilerHeatUp ($$$$$$)
sub ########################################
LUXTRONIK2_doStatisticBoilerCoolDown ($$$$$$)
{
- my ($hash, $time, $currTemp, $opState, $target, $threshold) = @_;
+ my ($hash, $time, $currTemp, $opState, $target, $threshold) = @_;
my $name = $hash->{NAME};
- my $step = $hash->{fhem}{statBoilerCoolDownStep};
+ my $step = $hash->{fhem}{statBoilerCoolDownStep};
my $maxTemp = $hash->{fhem}{statBoilerCoolDownMax};
my $startTime = $hash->{fhem}{statBoilerCoolDownStartTime};
- my $value1 = 0;
- my $value2 = 0;
- my $value3 = 0;
+ my $lastTime = $hash->{fhem}{statBoilerCoolDownLastTime};
+ my $lastTemp = $hash->{fhem}{statBoilerCoolDownLastTemp};
+ my $value1 = 0;
+ my $value2 = 0;
+ my $value3 = 0;
my $returnStr = "";
# step 0 = Initialize - if hot water preparation is off and target reached,
- if ($step == 0) {
+ if ($step == 0) {
if ($opState == 5 || $currTemp < $target) { # -> stay step 0
# Log3 $name, 4, "$name: Statistic Boiler Cool-Down step 0: Wait till hot water preparation stops and target is reached ($currTemp < $target)";
} else {
@@ -1246,34 +1330,262 @@ LUXTRONIK2_doStatisticBoilerCoolDown ($$$$$$)
$maxTemp = $currTemp;
}
# step 1 = wait till threshold is reached -> do calculation, monitor maximal temperature
- } elsif ($step == 1) {
- if ($currTemp > $maxTemp) { # monitor maximal temperature
- Log3 $name, 4, "$name: Statistic Boiler Cool-Down step 1: Temperature still increasing ($currTemp > $maxTemp)";
+ } elsif ($step == 1) {
+ if ($currTemp > $maxTemp) { # monitor maximal temperature
+ Log3 $name, 4, "$name: Statistic Boiler Cool-Down step 1: Temperature still increasing ($currTemp > $maxTemp)";
$maxTemp = $currTemp;
- $startTime = $time;
- }
- if ($opState == 5) {
- Log3 $name, 4, "$name: Statistic Boiler Cool-Down step 1: Measurement cancelled (restart of hot water preparation)";
- $step = 0;
- } elsif ($currTemp <= $threshold) {
- Log3 $name, 4, "$name: Statistic Boiler Cool-Down step 2->1: Measurement finished, threshold reached ($currTemp <= $threshold)";
- $value1 = ( int(10 * $currTemp) - int(10 * $maxTemp) ) / 10; # delta hot water temperature
- $value2 = ( $time - $startTime ) / 3600; # delta time (hours)
- $value3 = floor(100 * $value1 / $value2 + 0.5) / 100; # Temperature gradient over time rounded to 1/100th
- $value2 = floor(100 * $value2 + 0.5) / 100; # rounded to 1/100th
- $returnStr = "DT/h: $value3 DT: $value1 Dh: $value2";
+ $startTime = $time;
+ }
+ if ($opState == 5 || $currTemp <= $threshold) {
+ if ($opState == 5) {
+ Log3 $name, 4, "$name: Statistic Boiler Cool-Down step 1->0: Heat-up started, measurement finished";
+ $value1 = $lastTemp - $maxTemp; # delta hot water temperature
+ $value2 = ( $lastTime - $startTime ) / 3600; # delta time (hours)
+ } elsif ($currTemp <= $threshold) {
+ Log3 $name, 4, "$name: Statistic Boiler Cool-Down step 1->0: Measurement finished, threshold reached ($currTemp <= $threshold)";
+ $value1 = $currTemp - $maxTemp; # delta hot water temperature
+ $value2 = ( $time - $startTime ) / 3600; # delta time (hours)
+ }
+ $value3 = sprintf("%.2f", $value1 / $value2 ); # Temperature gradient over time rounded to 1/100th
+ $value2 = sprintf("%.2f", $value2 ); # rounded to 1/100th
+ $value1 = sprintf("%.1f", $value1 ); # rounded to 1/10th
+ $returnStr = "DT/h: $value3 DT: $value1 Dh: $value2";
+ $step = 0;
+ }
+ }
- $step = 0;
- }
- }
-
- $hash->{fhem}{statBoilerCoolDownStep} = $step;
+ $hash->{fhem}{statBoilerCoolDownStep} = $step;
$hash->{fhem}{statBoilerCoolDownMax} = $maxTemp;
$hash->{fhem}{statBoilerCoolDownStartTime} = $startTime;
+ $hash->{fhem}{statBoilerCoolDownLastTime} = $time;
+ $hash->{fhem}{statBoilerCoolDownLastTemp} = $currTemp;
return $returnStr;
}
+# Calculates single MaxMin Values and informs about end of day and month
+sub ########################################
+LUXTRONIK2_doStatisticMinMax ($$$)
+{
+ my ($hash, $readingName, $value) = @_;
+ my $dummy;
+ my $saveLast;
+ my $statReadingName;
+
+ my $lastReading;
+ my $lastSums;
+ my @newReading;
+
+ my $yearLast;
+ my $monthLast;
+ my $dayLast;
+ my $dayNow;
+ my $monthNow;
+ my $yearNow;
+
+ # Determine date of last and current reading
+ if (exists($hash->{READINGS}{$readingName."Day"}{TIME})) {
+ ($yearLast, $monthLast, $dayLast) = $hash->{READINGS}{$readingName."Day"}{TIME} =~ /^(\d\d\d\d)-(\d\d)-(\d\d)/;
+ } else {
+ ($dummy, $dummy, $dummy, $dayLast, $monthLast, $yearLast) = localtime;
+ $yearLast += 1900;
+ $monthLast ++;
+ }
+ ($dummy, $dummy, $dummy, $dayNow, $monthNow, $yearNow) = localtime;
+ $yearNow += 1900;
+ $monthNow ++;
+
+ # Daily Statistic
+ $saveLast = ($dayNow != $dayLast);
+ $statReadingName = $readingName."Day";
+ LUXTRONIK2_doStatisticMinMaxSingle $hash, $statReadingName, $value, $saveLast;
+
+ # Monthly Statistic
+ $saveLast = ($monthNow != $monthLast);
+ $statReadingName = $readingName."Month";
+ LUXTRONIK2_doStatisticMinMaxSingle $hash, $statReadingName, $value, $saveLast;
+
+ # Yearly Statistic
+ $saveLast = ($yearNow != $yearLast);
+ $statReadingName = $readingName."Year";
+ LUXTRONIK2_doStatisticMinMaxSingle $hash, $statReadingName, $value, $saveLast;
+
+ return ;
+
+}
+
+# Calculates single MaxMin Values and informs about end of day and month
+sub ########################################
+LUXTRONIK2_doStatisticMinMaxSingle ($$$$)
+{
+ my ($hash, $readingName, $value, $saveLast) = @_;
+ my $result;
+
+ my $lastReading = $hash->{READINGS}{$readingName}{VAL} || "";
+
+ # Initializing
+ if ( $lastReading eq "" ) {
+ my $since = strftime "%Y-%m-%d_%H:%M:%S", localtime();
+ $result = "Count: 1 Sum: $value ShowDate: 1";
+ readingsBulkUpdate($hash, ".".$readingName, $result);
+ $result = "Min: $value Avg: $value Max: $value (since: $since )";
+ readingsBulkUpdate($hash, $readingName, $result);
+
+ # Calculations
+ } else {
+ my @a = split / /, $hash->{READINGS}{"." . $readingName}{VAL}; # Internal values
+ my @b = split / /, $lastReading;
+ # Do calculations
+ if ($saveLast) {
+ readingsBulkUpdate($hash, $readingName . "Last", $lastReading);
+ $a[1] = 1; $a[3] = $value; $a[5] = 0;
+ $b[1] = $value; $b[3] = $value; $b[5] = $value;
+ } else {
+ $a[1]++; # Count
+ $a[3] += $value; # Sum
+ if ($value < $b[1]) { $b[1]=$value; } # Min
+ $b[3] = sprintf "%.1f" , $a[3] / $a[1]; # Avg
+ if ($value > $b[5]) { $b[5]=$value; } # Max
+ }
+ # Store internal calculation values
+ $result = "Count: $a[1] Sum: $a[3] ShowDate: $a[5]";
+ readingsBulkUpdate($hash, ".".$readingName, $result);
+ # Store visible Reading
+ if ($a[5] == 1) {
+ $result = "Min: $b[1] Avg: $b[3] Max: $b[5] (since: $b[7] )";
+ } else {
+ $result = "Min: $b[1] Avg: $b[3] Max: $b[5]";
+ }
+ readingsBulkUpdate($hash, $readingName, $result);
+ }
+ return;
+}
+
+
+sub ########################################
+LUXTRONIK2_storeReadings($$$$$)
+{
+ my ($hash, $readingName, $value, $factor, $doStatistics) = @_;
+
+ if ($value eq "no" || $value == 0 ) { return; }
+
+ readingsBulkUpdate($hash, $readingName, sprintf("%.1f", $value / $factor));
+
+ $readingName =~ s/counter//;
+
+ # LUXTRONIK2_doStatisticDelta: $hash, $readingName, $value, $factor
+ if ( $doStatistics == 1) { LUXTRONIK2_doStatisticDelta $hash, "stat".$readingName, $value, $factor; }
+}
+
+
+# Calculates deltas for day, month and year
+sub ########################################
+LUXTRONIK2_doStatisticDelta ($$$$)
+{
+ my ($hash, $readingName, $value, $factor) = @_;
+ my $dummy;
+
+ my @curr = split / /, $hash->{READINGS}{$readingName}{VAL} || "";
+ my @start = split / /, $hash->{READINGS}{"." . $readingName . "Start"}{VAL} || "";
+
+ my $saveLast=0;
+ my @last;
+ if (exists ($hash->{READINGS}{$readingName."Last"})) {
+ @last = split / /, $hash->{READINGS}{$readingName."Last"}{VAL};
+ } else {
+ @last = split / /, "Day: - Month: - Year: -";
+ }
+
+ my $result;
+ my $yearLast;
+ my $monthLast;
+ my $dayLast;
+ my $dayNow;
+ my $monthNow;
+ my $yearNow;
+
+ # Determine date of last and current reading
+ if (exists($hash->{READINGS}{$readingName}{TIME})) {
+ ($yearLast, $monthLast, $dayLast) = ($hash->{READINGS}{$readingName}{TIME} =~ /^(\d\d\d\d)-(\d\d)-(\d\d)/);
+ } else {
+ ($dummy, $dummy, $dummy, $dayLast, $monthLast, $yearLast) = localtime;
+ $yearLast += 1900;
+ $monthLast ++;
+ $start[1] = $value;
+ $start[3] = $value;
+ $start[5] = $value;
+ $start[7] = 6;
+ $curr[7] = strftime "%Y-%m-%d_%H:%M:%S", localtime(); # Start
+ }
+ ($dummy, $dummy, $dummy, $dayNow, $monthNow, $yearNow) = localtime;
+ $yearNow += 1900;
+ $monthNow ++;
+
+ # Yearly Statistic
+ if ($yearNow != $yearLast){
+ $last[5] = $curr[5];
+ $start[5] = $value;
+ # Do not show the "since:" value for year changes anymore
+ if ($start[7] == 1) { $start[7] = 0; }
+ # Shows the "since:" value for the first year change
+ if ($start[7] >= 2) {
+ $last[7] = $curr[7];
+ $start[7] = 1;
+ }
+ }
+ $curr[5] = sprintf "%.1f", ($value - $start[5]) / $factor;
+
+ # Monthly Statistic
+ if ($monthNow != $monthLast){
+ $last[3] = $curr[3];
+ $start[3] = $value;
+ # Do not show the "since:" value for month changes anymore
+ if ($start[7] == 3) { $start[7] = 2; }
+ # Shows the "since:" value for the first month change
+ if ($start[7] >= 4) {
+ $last[7] = $curr[7];
+ $start[7] = 3;
+ }
+ }
+ $curr[3] = sprintf "%.1f", ($value - $start[3]) / $factor;
+
+ # Daily Statistic
+ if ($dayNow != $dayLast){
+ $last[1] = $curr[1];
+ $start[1] = $value;
+ # Do not show the "since:" value for day changes anymore
+ if ($start[7] == 5) { $start[7] = 4; }
+ # Shows the "since:" value for the first day change
+ if ($start[7] >= 6) {
+ $last[7] = $curr[7];
+ $start[7] = 5;
+ # Next monthly and yearly values start at 00:00
+ $curr[7] = strftime "%Y-%m-%d", localtime(); # Start
+ $start[3] = $value;
+ $start[5] = $value;
+ }
+ $saveLast = 1;
+ }
+ $curr[1] = sprintf "%.1f", ($value - $start[1]) / $factor;
+
+ # Store internal calculation values
+ $result = "Day: $start[1] Month: $start[3] Year: $start[5] ShowDate: $start[7]";
+ readingsBulkUpdate($hash, ".".$readingName."Start", $result);
+
+ # Store visible Reading
+ $result = "Day: $curr[1] Month: $curr[3] Year: $curr[5]";
+ if ($start[7] != 0 ) { $result .= " (since: $curr[7] )"; }
+ readingsBulkUpdate($hash,$readingName,$result);
+
+ if ($saveLast == 1) {
+ $result = "Day: $last[1] Month: $last[3] Year: $last[5]";
+ if ( $start[7] =~ /1|3|5/ ) { $result .= " (since: $last[7] )";}
+ readingsBulkUpdate($hash,$readingName."Last",$result);
+ }
+
+ return ;
+}
+
1;
@@ -1283,7 +1595,7 @@ LUXTRONIK2_doStatisticBoilerCoolDown ($$$$$$)
LUXTRONIK2
- Luxtronik 2.0 is a heating controller used in Alpha Innotec and Siemens Novelan (WPR NET) heat pumps.
+ Luxtronik 2.0 is a heating controller used in Alpha Innotec, Siemens Novelan (WPR NET) and Wolf Heiztechnik (BWL/BWS) heat pumps.
It has a built-in ethernet port, so it can be directly integrated into a local area network (LAN).
@@ -1306,13 +1618,17 @@ LUXTRONIK2_doStatisticBoilerCoolDown ($$$$$$)
Set
A firmware check assures before each set operation that a heat pump with untested firmware is not damaged accidently.
opModeHotWater <Mode>
- Operating Mode of domestic hot water boiler (Auto | Party | Off)
+ Operating Mode of domestic hot water boiler (Auto | Party | Off)
+
hotWaterTemperatureTarget <temperature>
- Target temperature of domestic hot water boiler in °C
+ Target temperature of domestic hot water boiler in °C
+
INTERVAL <polling interval>
- Polling interval in seconds
+ Polling interval in seconds
+
statusRequest
- Update device information
+ Update device information
+
synchClockHeatPump
Synchronizes controller clock with FHEM time. !! This change is lost in case of controller power off!!
@@ -1332,13 +1648,20 @@ LUXTRONIK2_doStatisticBoilerCoolDown ($$$$$$)
If set, a HTML-formatted reading named "floorplanHTML" is created. It can be used with the FLOORPLAN module.
- Currently, if the value of this attribute is not NULL, the corresponding reading consists of the current status of the heat pump and the temperature of the water.
+ Currently, if the value of this attribute is not NULL, the corresponding reading consists of the current status of the heat pump and the temperature of the water.
+
doStatistics < 0 | 1 >
- Calculates statistic values: statBoilerGradientHeatUp, statBoilerGradientCoolDown, statBoilerGradientCoolDownMin (boiler heat loss)
+ Calculates statistic values: statBoilerGradientHeatUp, statBoilerGradientCoolDown, statBoilerGradientCoolDownMin (boiler heat loss)
+
+ Builds daily, monthly and yearly statistics for certain readings (average/min/max or cumulated values).
+
+ Logging and visualisation of the statistic should be done with readings of type 'statReadingNameLast'.
+
allowSetParameter < 0 | 1 >
- The parameters of the heat pump controller can only be changed if this attribut is set to 1.
+ The parameters of the heat pump controller can only be changed if this attribut is set to 1.
+
autoSynchClock <delay>
Corrects the clock of the heatpump automatically if a certain delay (10 s - 600 s) against the FHEM time is exeeded. Does a firmware check before.
@@ -1348,7 +1671,8 @@ LUXTRONIK2_doStatisticBoilerCoolDown ($$$$$$)
A firmware check assures before each set operation that a heatpump controller with untested firmware is not damaged accidently.
- If this attribute is set to 1, the firmware check is ignored and new firmware can be tested for compatibility.
+ If this attribute is set to 1, the firmware check is ignored and new firmware can be tested for compatibility.
+
- readingFnAttributes
@@ -1360,8 +1684,11 @@ LUXTRONIK2_doStatisticBoilerCoolDown ($$$$$$)
LUXTRONIK2
- Die Luxtronik 2.0 ist eine Heizungssteuerung, welche in Wärmepumpen von Alpha Innotec und Siemens Novelan (WPR NET) verbaut ist.
- Sie besitzt einen Ethernet Anschluss, so dass sie direkt in lokale Netzwerke (LAN) integriert werden kann.
+ Die Luxtronik 2.0 ist eine Heizungssteuerung, welche in Wärmepumpen von Alpha Innotec,
+ Siemens Novelan (WPR NET) und Wolf Heiztechnik (BWL/BWS) verbaut ist.
+
+ Sie besitzt einen Ethernet Anschluss, so dass sie direkt in lokale Netzwerke (LAN) integriert werden kann.
+
Das Modul wurde bisher mit folgender Steuerungs-Firmware getestet: V1.54C, V1.60, V1.69.
@@ -1384,16 +1711,20 @@ LUXTRONIK2_doStatisticBoilerCoolDown ($$$$$$)
Durch einen Firmware-Test wird vor jeder Set-Operation sichergestellt, dass Wärmepumpen mit ungetester Firmware nicht unabsichtlich beschädigt werden.
opModeHotWater <Betriebsmodus>
- Betriebsmodus des Heißwasserboilers ( Auto | Party | Off )
+ Betriebsmodus des Heißwasserboilers ( Auto | Party | Off )
+
hotWaterTemperatureTarget <Temperatur>
- Soll-Temperatur des Heißwasserboilers in °C
+ Soll-Temperatur des Heißwasserboilers in °C
+
INTERVAL <Abfrageinterval>
- Abfrageinterval in Sekunden
+ Abfrageinterval in Sekunden
+
statusRequest
- Aktualisieren der Gerätewerte
+ Aktualisieren der Gerätewerte
+
synchClockHeatPump
Abgleich der Uhr der Steuerung mit der FHEM Zeit. Diese Änderung geht verloren, sobald die Steuerung ausgeschaltet wird!!
@@ -1414,27 +1745,35 @@ LUXTRONIK2_doStatisticBoilerCoolDown ($$$$$$)
wenn gesetzt, dann wird ein HTML-formatierter Wert "floorplanHTML" erzeugt,
welcher vom Modul FLOORPLAN genutzt werden kann.
Momentan wird nur geprüft, ob der Wert dieses Attributes ungleich NULL ist,
- der entsprechende Gerätewerte besteht aus dem aktuellen Wärmepumpenstatus und der Heizwassertemperatur.
+ der entsprechende Gerätewerte besteht aus dem aktuellen Wärmepumpenstatus und der Heizwassertemperatur.
+
doStatistics < 0 | 1 >
Berechnet statistische Werte: statBoilerGradientHeatUp, statBoilerGradientCoolDown,
- statBoilerGradientCoolDownMin (Wärmeverlust des Boilers)
+ statBoilerGradientCoolDownMin (Wärmeverlust des Boilers)
+
+ Bildet tägliche, monatliche und jährliche Statistiken bestimmter Gerätewerte.
+ Für grafische Auswertungen können die Werte der Form 'statReadingNameLast' genutzt werden.
+
allowSetParameter < 0 | 1 >
Die internen Parameter der Wärmepumpensteuerung können
- nur geändert werden, wenn dieses Attribut auf 1 gesetzt ist.
+ nur geändert werden, wenn dieses Attribut auf 1 gesetzt ist.
+
autoSynchClock <Zeitunterschied>
Die Uhr der Wärmepumpe wird automatisch korrigiert, wenn ein gewisser Zeitunterschied (10 s - 600 s)
gegenüber der FHEM Zeit erreicht ist. Zuvor wird die Kompatibilität der Firmware überprüft.
(Ein Gerätewert 'delayDeviceTimeCalc' <= 2 s ist auf die internen Berechnungsintervale der
- Wärmepumpensteuerung zurückzuführen.)
+ Wärmepumpensteuerung zurückzuführen.)
+
ignoreFirmwareCheck < 0 | 1 >
Durch einen Firmware-Test wird vor jeder Set-Operation sichergestellt, dass Wärmepumpen
mit ungetester Firmware nicht unabsichtlich beschädigt werden. Wenn dieses Attribute auf 1
gesetzt ist, dann wird der Firmware-Test ignoriert und neue Firmware kann getestet werden.
- Dieses Attribut wird jedoch ignoriert, wenn die Steuerungs-Firmware bereits als nicht kompatibel berichtet wurde.
+ Dieses Attribut wird jedoch ignoriert, wenn die Steuerungs-Firmware bereits als nicht kompatibel berichtet wurde.
+
- readingFnAttributes