mirror of
https://github.com/fhem/fhem-mirror.git
synced 2025-02-26 10:34:52 +00:00
LUXTRONIK2: new feature: set ventBOSUPCircPumpDeaerate
git-svn-id: https://svn.fhem.de/fhem/trunk@24860 2b470e98-0d58-463d-a4d8-8e2adae1ed80
This commit is contained in:
parent
0061ef3dc7
commit
1fae94b555
@ -1,5 +1,6 @@
|
||||
# Add changes at the top of the list. Keep it in ASCII, and 80-char wide.
|
||||
# Do not insert empty lines here, update check depends on it.
|
||||
- feature: 23_LUXTRONIK2: new set parameter ventBOSUPCircPumpDeaerate
|
||||
- bugfix: 73_DoorBird: Firmware update parsing fixed
|
||||
- change: 70_VIERA: changed Commandref
|
||||
- feature: 23_LUXTRONIK2: addded support for firmware V1.86.2
|
||||
|
@ -3,6 +3,7 @@
|
||||
#
|
||||
# 23_LUXTRONIK2.pm
|
||||
#
|
||||
# (c) 2020-2021 Thomas Heiser
|
||||
# (c) 2012-2017 Torsten Poitzsch
|
||||
# (c) 2012-2013 Jan-Hinrich Fessel (oskar at fessel . org)
|
||||
#
|
||||
@ -292,14 +293,15 @@ LUXTRONIK2_Set($$@)
|
||||
}
|
||||
# Einstellung->Entlüftung
|
||||
elsif( int(@_)==4 &&
|
||||
( $cmd eq 'hotWaterCircPumpDeaerate' || $cmd eq 'heatingSystemCircPumpDeaerate' ) ) {
|
||||
( $cmd eq 'hotWaterCircPumpDeaerate' || $cmd eq 'heatingSystemCircPumpDeaerate' || $cmd eq 'ventBOSUPCircPumpDeaerate' ) ) {
|
||||
Log3 $name, 3, "set $name $cmd $val";
|
||||
return "$name Error: Wrong parameter given - use on,off" if $val !~ /on|off/;
|
||||
$hash->{LOCAL} = 1;
|
||||
$resultStr = LUXTRONIK2_SetParameter ($hash, $cmd, $val);
|
||||
if( $val eq "on"
|
||||
|| ReadingsVal( $name, "heatingSystemCircPumpDeaerate", "off" ) eq "on"
|
||||
|| ReadingsVal( $name, "hotWaterCircPumpDeaerate", "off" ) eq "on" ) {
|
||||
|| ReadingsVal( $name, "hotWaterCircPumpDeaerate", "off" ) eq "on"
|
||||
|| ReadingsVal( $name, "ventBOSUPCircPumpDeaerate", "off" ) eq "on" ) {
|
||||
$resultStr .= LUXTRONIK2_SetParameter ($hash, "runDeaerate", 1);
|
||||
}
|
||||
# only send "0" if no Deaerate checkbox is selected at all.
|
||||
@ -316,6 +318,7 @@ LUXTRONIK2_Set($$@)
|
||||
." heatingCurveEndPoint"
|
||||
." heatingCurveOffset"
|
||||
." heatingSystemCircPumpDeaerate:on,off"
|
||||
." ventBOSUPCircPumpDeaerate:on,off"
|
||||
." heatSourceDefrostAirEnd"
|
||||
." heatSourceDefrostAirThreshold"
|
||||
." hotWaterCircPumpDeaerate:on,off"
|
||||
@ -623,6 +626,8 @@ sub LUXTRONIK2_DoUpdate($)
|
||||
$return_str .= "|".($heatpump_visibility[4]==1 ? $heatpump_parameters[894] : "no");;
|
||||
# 80 - heatingSystemCircPumpDeaerate
|
||||
$return_str .= "|". ($heatpump_visibility[161]==1 ? $heatpump_parameters[678] : "no");
|
||||
# 81 - ventBOSUPCircPumpDeaerate
|
||||
$return_str .= "|". ($heatpump_visibility[161]==1 ? $heatpump_parameters[681] : "no");
|
||||
|
||||
return $return_str;
|
||||
}
|
||||
@ -1059,6 +1064,7 @@ LUXTRONIK2_UpdateDone($)
|
||||
# Deaerate Function
|
||||
readingsBulkUpdate( $hash, "hotWaterCircPumpDeaerate",$a[61]?"on":"off") unless $a[61] eq "no";
|
||||
readingsBulkUpdate( $hash, "heatingSystemCircPumpDeaerate",$a[80]?"on":"off") unless $a[80] eq "no";
|
||||
readingsBulkUpdate( $hash, "ventBOSUPCircPumpDeaerate",$a[81]?"on":"off") unless $a[81] eq "no";
|
||||
|
||||
# bivalentLevel
|
||||
readingsBulkUpdate($hash,"bivalentLevel",$a[43]);
|
||||
@ -1509,6 +1515,10 @@ sub LUXTRONIK2_SetParameter ($$$)
|
||||
$setParameter = 684;
|
||||
$setValue = $realValue eq "on" ? 1 : 0;
|
||||
}
|
||||
elsif ($parameterName eq "ventBOSUPCircPumpDeaerate") { #isVisible(167)
|
||||
$setParameter = 681;
|
||||
$setValue = $realValue eq "on" ? 1 : 0;
|
||||
}
|
||||
elsif ($parameterName eq "runDeaerate") {
|
||||
$setParameter = 158;
|
||||
$setValue = $realValue;
|
||||
@ -2294,6 +2304,11 @@ LUXTRONIK2_doStatisticDeltaSingle ($$$$$$$)
|
||||
<br>
|
||||
NOTE! It uses the deaerate function of the controller. So, the pump alternates always 5 minutes on and 5 minutes off.
|
||||
</li><br>
|
||||
<li><code>ventBOSUPCircPumpDeaerate <on | off></code><br>
|
||||
Switches the BOSUP circuit circulation pump on or off.
|
||||
<br>
|
||||
NOTE! It uses the deaerate function of the controller. So, the pump alternates always 5 minutes on and 5 minutes off.
|
||||
</li><br>
|
||||
<li><code>hotWaterTemperatureTarget <temperature></code><br>
|
||||
Target temperature of domestic hot water boiler in °C
|
||||
</li><br>
|
||||
@ -2457,6 +2472,11 @@ LUXTRONIK2_doStatisticDeltaSingle ($$$$$$$)
|
||||
<br>
|
||||
Achtung! Es wird die Entlüftungsfunktion der Steuerung genutzt. Dadurch taktet die Pumpe jeweils 5 Minuten ein und 5 Minuten aus.
|
||||
</li><br>
|
||||
<li><code>ventBOSUPCircPumpDeaerate <on | off></code><br>
|
||||
Schaltet die Umwälzpumpe des BOSUP an oder aus.
|
||||
<br>
|
||||
Achtung! Es wird die Entlüftungsfunktion der Steuerung genutzt. Dadurch taktet die Pumpe jeweils 5 Minuten ein und 5 Minuten aus.
|
||||
</li><br>
|
||||
<li><code>hotWaterTemperatureTarget <Temperatur></code>
|
||||
<br>
|
||||
Soll-Temperatur des Heißwasserspeichers in °C
|
||||
|