@ -266,8 +266,10 @@ THRESHOLD_Set($@)
if ($arg eq "desired" ) {
return "$pn: set desired value:$value, desired value needs a numeric parameter" if(@a != 3 || $value !~ m/^[-\d\.]*$/);
return $ret if ($desired_value == $value);
Log3 $pn,2, "set $pn $arg $value";
if ($desired_value ne "") {
return $ret if ($desired_value == $value);
}
Log3 $pn,2, "set $pn $arg $value";
$mode = "active";
$state_format =~ s/\_m/$mode/g;
$state_format =~ s/\_dv/$value/g;
@ -284,7 +286,7 @@ THRESHOLD_Set($@)
readingsBulkUpdate ($hash, "desired_value", $value);
readingsEndUpdate ($hash, 1);
} elsif ($arg eq "deactivated" ) {
return "$pn: set deactivated, set desired value first" if (!$desired_value);
return "$pn: set deactivated, set desired value first" if ($desired_value eq "");
$ret=CommandAttr(undef, "$pn disable 1");
if (!$ret) {
readingsBeginUpdate ($hash);
@ -299,7 +301,7 @@ THRESHOLD_Set($@)
readingsEndUpdate ($hash, 1);
}
} elsif ($arg eq "active" ) {
return "$pn: set active, set desired value first" if (!$desired_value);
return "$pn: set active, set desired value first" if ($desired_value eq "");
$ret=CommandDeleteAttr(undef, "$pn disable");
if (!$ret) {
$mode="active";
@ -333,7 +335,7 @@ THRESHOLD_Set($@)
} elsif ($arg eq "hysteresis" ) {
return "$pn: set hysteresis value:$value, hysteresis needs a numeric parameter" if (@a != 3 || $value !~ m/^[\d\.]*$/ );
$hash->{hysteresis} = $value;
if ($desired_value) {
if ($desired_value ne "") {
readingsBeginUpdate ($hash);
readingsBulkUpdate ($hash, "threshold_min",$desired_value-$hash->{hysteresis}+$offset);
readingsBulkUpdate ($hash, "threshold_max", $desired_value+$offset);
@ -344,7 +346,7 @@ THRESHOLD_Set($@)
return "$pn: set offset value:$value, offset needs a numeric parameter" if (@a != 3 || $value !~ m/^[-\d\.]*$/ );
$offset = $value;
$hash->{offset} = $offset;
if ($desired_value) {
if ($desired_value ne "") {
readingsBeginUpdate ($hash);
readingsBulkUpdate ($hash, "threshold_min",$desired_value-$hash->{hysteresis}+$offset);
readingsBulkUpdate ($hash, "threshold_max", $desired_value+$offset);
@ -388,9 +390,9 @@ THRESHOLD_Notify($$)
my $name = $dev->{NAME};
SELECT:{
if (($name eq $sensor) and ReadingsVal($pn,"desired_value","")) {last SELECT;}
if (($name eq $sensor) and (ReadingsVal($pn,"desired_value","") ne "")) {last SELECT;}
if ($sensor2) {
if (($name eq $sensor2) and ReadingsVal($pn,"desired_value","")) {last SELECT;}
if (($name eq $sensor2) and (ReadingsVal($pn,"desired_value","") ne "")) {last SELECT;}
}
if ($target_sensor) {
if (ReadingsVal($pn,"mode","") eq "external") {
@ -626,8 +628,9 @@ THRESHOLD_setValue($$)
<br>
<br>
<li><b>AND|OR</b> (optional)<br>
logical operator with an optional second sensor
logical operator with an optional second sensor<br>
</li>
<br>
<li><b>sensor2</b> (optional, nur in Verbindung mit AND oder OR)<br>
the second sensor
</li>
@ -765,7 +768,7 @@ THRESHOLD_setValue($$)
It should be heated when the room temperature drops below 21 degrees and the outside temperature is below 15 degrees:<br>
<br>
<code>define TH_outdoor THRESHOLD outdoor:temperature:0:15</code><br>
<code>define TH_room THRESHOLD indoor AND TH_outdoor:state:on heating</code><br>
<code>define TH_room THRESHOLD indoor OR TH_outdoor:state:off heating</code><br>
<code>set TH_room desired 21</code><br>
<br>
<br>
@ -873,7 +876,7 @@ THRESHOLD_setValue($$)
Das Modul beginnt mit der Steuerung erst dann, wenn ein Sollwert gesetzt wird!<br>
<br>
Alternativ kann die Vorgabe des Sollwertes von einem weiteren Sensor kommen. Damit kann eine Steuerung durch den Vergleich zweier Sensoren stattfinden.
Typisches Anwendungsbeispiel ist z. B. die Steuerung von Umwelz- oder Zirkulationspumpen.<br>
Typisches Anwendungsbeispiel ist z. B. die Steuerung von Umwälz- oder Zirkulationspumpen.<br>
<br>
Ebenso können beliebige Wandthermostate (z. B. HM, MAX, FHT) für die Vorgabe der Solltemperatur genutzt werden.<br>
<br>
@ -1055,7 +1058,7 @@ THRESHOLD_setValue($$)
Es soll geheizt werden, wenn die Zimmertemperatur unter 21 Grad fällt und die Außentemperatur unter 15 Grad ist:<br>
<br>
<code>define TH_outdoor THRESHOLD outdoor:temperature:0:15</code><br>
<code>define TH_room THRESHOLD indoor AND TH_outdoor:state:on heating</code><br>
<code>define TH_room THRESHOLD indoor OR TH_outdoor:state:off heating</code><br>
<code>set TH_room desired 21</code><br>
<br>
<br>