@ -32,6 +32,11 @@ eval "use FHEM::Meta;1" or my $modMetaAbsent = 1;
# Versions History by DS_Starter
our %SMAInverter_vNotesIntern = (
"2.20.2" => "12.01.2023 new read SPOT_EPVTOTAL / SPOT_EPVTODAY (Hybrid Inverter)",
"2.20.1" => "09.01.2023 fix BAT_UNLOADTODAY calculate",
"2.20.0" => "08.01.2023 crypt Password",
"2.19.1" => "07.01.2023 new read BAT_UNLOADTODAY / BAT_UNLOADTOTAL, included by 300P,",
"2.19.0" => "04.01.2023 new read BAT_CAPACITY, included by 300P,",
"2.18.3" => "11.10.2022 fix new ETOTAL/LOADTOTAL bug 2.0 ;)",
"2.18.2" => "09.10.2022 fix new ETOTAL/LOADTOTAL bug",
"2.18.1" => "03.10.2022 new SE Inverters fix BAT-Data, fix ETODAY bug",
@ -138,6 +143,9 @@ our %SMAInverter_vNotesIntern = (
# $inv_STATUS # Inverter Status
# $inv_BAT_LOADTODAY # Today Batteryload
# $inv_BAT_LOADTOTAL # Total Batteryload
# $inv_BAT_CAPACITY # Battery Capacity (Percent) #TTT
# $inv_BAT_UNLOADTODAY # Today Batteryunload
# $inv_BAT_UNLOADTOTAL # Total Batteryunload
# Aufbau Wechselrichter Type-Hash
# https://github.com/SBFspot/SBFspot/blob/master/SBFspot/TagListDE-DE.txt
@ -373,6 +381,7 @@ sub SMAInverter_Define($$) {
my ($IP,$Host,$Caps);
my $Pass = $a[2]; # to do: check 1-12 Chars
my $password = SMAInverter_SMAencrypt($Pass);
# extract IP or Hostname from $a[3]
if (!defined $Host) {
@ -385,7 +394,8 @@ sub SMAInverter_Define($$) {
return "Argument:{$a[3]} not accepted as Host or IP. Read device specific help file.";
}
$hash->{PASS} = $Pass;
$hash->{DEF} = "$password $Host";
$hash->{PASS} = $password;
$hash->{HOST} = $Host;
InternalTimer(gettimeofday()+5, "SMAInverter_GetData", $hash, 0); # Start Hauptroutine
@ -492,6 +502,50 @@ sub SMAInverter_Attr(@) {
return;
}
##########################################################################
# Encrypt Passwort/Username übernommen aus 76_SMAEVCharger.pm author: Jürgen Allmich
##########################################################################
sub SMAInverter_SMAencrypt($)
{
my ($decoded) = @_;
my $key = getUniqueId();
my $encoded;
return $decoded if( $decoded =~ /crypt:/ );
for my $char (split //, $decoded) {
my $encode = chop($key);
$encoded .= sprintf("%.2x",ord($char)^ord($encode));
$key = $encode.$key;
}
return 'crypt:'.$encoded;
}
##########################################################################
# Decrypt Passwort/Username übernommen aus 76_SMAEVCharger.pm author: Jürgen Allmich
##########################################################################
sub SMAInverter_SMAdecrypt($)
{
my ($encoded) = @_;
my $key = getUniqueId();
my $decoded;
return $encoded if( $encoded !~ /crypt:/ );
$encoded = $1 if( $encoded =~ /crypt:(.*)/ );
for my $char (map { pack('C', hex($_)) } ($encoded =~ /(..)/g)) {
my $decode = chop($key);
$decoded .= chr(ord($char)^ord($decode));
$key = $decode.$key;
}
return $decoded;
}
###############################################################
# Hauptschleife Datenabruf
###############################################################
@ -541,6 +595,7 @@ sub SMAInverter_getstatusDoParse($) {
my $interval = AttrVal($name, "interval", 60);
my $sc = AttrVal($name, "SBFSpotComp", 0);
my ($sup_EnergyProduction,
$sup_PVEnergyProduction,
$sup_SpotDCPower,
$sup_SpotACPower,
$sup_MaxACPower,
@ -555,6 +610,7 @@ sub SMAInverter_getstatusDoParse($) {
$sup_BatteryInfo_TEMP,
$sup_BatteryInfo_UDC,
$sup_BatteryInfo_IDC,
$sup_BatteryInfo_Capacity,
$sup_BatteryInfo_Capac,
$sup_SpotGridFrequency,
$sup_TypeLabel,
@ -562,10 +618,12 @@ sub SMAInverter_getstatusDoParse($) {
$sup_InverterTemperature,
$sup_GridRelayStatus,
$sup_SpotBatteryLoad,
$sup_SpotBatteryUnload,
$sup_DeviceStatus);
my ($inv_TYPE, $inv_CLASS,
$inv_SPOT_ETODAY, $inv_SPOT_ETOTAL,
$inv_SPOT_EPVTODAY, $inv_SPOT_EPVTOTAL,
$inv_susyid,
$inv_serial,
$inv_SPOT_PDC1, $inv_SPOT_PDC2,
@ -582,7 +640,7 @@ sub SMAInverter_getstatusDoParse($) {
$inv_BAT_IDC, $inv_BAT_IDC_A, $inv_BAT_IDC_B, $inv_BAT_IDC_C,
$inv_BAT_CYCLES, $inv_BAT_CYCLES_A, $inv_BAT_CYCLES_B, $inv_BAT_CYCLES_C,
$inv_BAT_TEMP, $inv_BAT_TEMP_A, $inv_BAT_TEMP_B, $inv_BAT_TEMP_C,
$inv_BAT_LOADTODAY, $inv_BAT_LOADTOTAL,
$inv_BAT_LOADTODAY, $inv_BAT_LOADTOTAL, $inv_BAT_CAPACITY,$inv_BAT_UNLOADTODAY,$inv_BAT_UNLOADTOTAL,
$inv_SPOT_FREQ, $inv_SPOT_OPERTM, $inv_SPOT_FEEDTM, $inv_TEMP, $inv_GRIDRELAY, $inv_STATUS,);
my @row_array;
@ -593,6 +651,8 @@ sub SMAInverter_getstatusDoParse($) {
# Background-Startzeit
$bst = [gettimeofday];
$inv_CLASS = ReadingsVal($name,"INV_CLASS","");
Log3 ($name, 4, "$name -> Start BlockingCall SMAInverter_getstatusDoParse");
# set dependency from surise/sunset used for inverter operation time
@ -622,14 +682,29 @@ sub SMAInverter_getstatusDoParse($) {
BlockingInformParent("SMAInverter_setReadingFromBlocking", [$name, ".etotal_yesterday", $val], 0);
}
# EPVTOTAL speichern für EPVTODAY-Berechnung wenn WR EPVTODAY nicht liefert
if ($dt_now <= $oper_start_d && ($inv_CLASS eq "Hybrid Inverters" || $inv_CLASS eq "Hybrid-Wechselrichter")) {
my $val = 0;
$val = ReadingsNum($name, "epvtotal", 0)*1000 if (exists $defs{$name}{READINGS}{epvtotal});
$val = ReadingsNum($name, "SPOT_EPVTOTAL", 0) if (exists $defs{$name}{READINGS}{SPOT_EPVTOTAL});
BlockingInformParent("SMAInverter_setReadingFromBlocking", [$name, ".epvtotal_yesterday", $val], 0);
}
# BATTERYLOAD_TOTAL speichern für BAT_LOADTODAY-Berechnung wenn WR BAT_LOADTODAY nicht liefert
if ($dt_now <= $oper_start_d) { # V2.14.1, Forum: https://forum.fhem.de/index.php/topic,56080.msg1134664.html#msg1134664
if ($dt_now <= $oper_start_d) {
my $val = 0;
$val = ReadingsNum($name, "bat_loadtotal", 0)*1000 if (exists $defs{$name}{READINGS}{bat_loadtotal});
$val = ReadingsNum($name, "BAT_LOADTOTAL", 0) if (exists $defs{$name}{READINGS}{BAT_LOADTOTAL});
BlockingInformParent("SMAInverter_setReadingFromBlocking", [$name, ".bat_loadtotal_yesterday", $val], 0);
}
# BATTERYUNLOAD_TOTAL speichern für BAT_UNLOADTODAY-Berechnung wenn WR BAT_UNLOADTODAY nicht liefert
if ($dt_now <= $oper_start_d) { # V2.14.1, Forum: https://forum.fhem.de/index.php/topic,56080.msg1134664.html#msg1134664
my $val = 0;
$val = ReadingsNum($name, "bat_unloadtotal", 0)*1000 if (exists $defs{$name}{READINGS}{bat_unloadtotal});
$val = ReadingsNum($name, "BAT_UNLOADTOTAL", 0) if (exists $defs{$name}{READINGS}{BAT_UNLOADTOTAL});
BlockingInformParent("SMAInverter_setReadingFromBlocking", [$name, ".bat_unloadtotal_yesterday", $val], 0);
}
if (($oper_start <= $dt_now && $dt_now <= $oper_stop) || AttrVal($name,"suppressSleep",0)) {
# normal operation or suppressed sleepmode
@ -648,6 +723,8 @@ sub SMAInverter_getstatusDoParse($) {
"sup_ChargeStatus" # Check BatteryChargeStatus
);
push(@commands, "sup_PVEnergyProduction") if($inv_CLASS eq "Hybrid Inverters" || $inv_CLASS eq "Hybrid-Wechselrichter"); # Check PV-EnergyProduction (Hybrid Inverter)
if($detail_level > 0) {
# Detail Level 1 or 2 >> get voltage and current levels
push(@commands, "sup_SpotDCVoltage"); # Check SpotDCVoltage
@ -669,6 +746,7 @@ sub SMAInverter_getstatusDoParse($) {
}
push(@commands, "sup_SpotBatteryLoad"); # Check Batteryload
push(@commands, "sup_SpotBatteryUnload"); # Check BatteryUnload
}
if($detail_level > 1) {
@ -680,6 +758,7 @@ sub SMAInverter_getstatusDoParse($) {
push(@commands, "sup_MaxACPower2"); # Check MaxACPower2 ?
push(@commands, "sup_GridRelayStatus"); # Check GridRelayStatus
push(@commands, "sup_DeviceStatus"); # Check DeviceStatus
push(@commands, "sup_BatteryInfo_Capacity"); # Check DeviceCapacity - Battery
if (ReadingsVal($name,"INV_TYPE","") =~ /SBS(6\.0|5\.0|3\.7)/xs || ReadingsVal($name,"device_type","") =~ /SBS(6\.0|5\.0|3\.7)/xs)
{
@ -700,6 +779,9 @@ sub SMAInverter_getstatusDoParse($) {
}
elsif ($i eq "sup_EnergyProduction") {
($sup_EnergyProduction,$inv_SPOT_ETODAY,$inv_SPOT_ETOTAL,$inv_susyid,$inv_serial) = SMAInverter_SMAcommand($hash, $hash->{HOST}, 0x54000200, 0x00260100, 0x002622FF);
}
elsif ($i eq "sup_PVEnergyProduction") {
($sup_PVEnergyProduction,$inv_SPOT_EPVTODAY,$inv_SPOT_EPVTOTAL,$inv_susyid,$inv_serial) = SMAInverter_SMAcommand($hash, $hash->{HOST}, 0x54000200, 0x0046c300, 0x0046c3FF);
}
elsif ($i eq "sup_SpotDCPower") {
($sup_SpotDCPower,$inv_SPOT_PDC1,$inv_SPOT_PDC2,$inv_susyid,$inv_serial) = SMAInverter_SMAcommand($hash, $hash->{HOST}, 0x53800200, 0x00251E00, 0x00251EFF);
@ -735,6 +817,10 @@ sub SMAInverter_getstatusDoParse($) {
Log3 $name, 5, "$name -> sup_BatteryInfo_IDC";
($sup_BatteryInfo_IDC,$inv_BAT_IDC,$inv_BAT_IDC_A,$inv_BAT_IDC_B,$inv_BAT_IDC_C,$inv_susyid,$inv_serial) = SMAInverter_SMAcommand($hash, $hash->{HOST}, 0x51000200, 0x00495D00, 0x00495D10);
}
elsif ($i eq "sup_BatteryInfo_Capacity") {
Log3 $name, 5, "$name -> sup_BatteryInfo_Capacity";
($sup_BatteryInfo_Capacity,$inv_BAT_CAPACITY,$inv_susyid,$inv_serial) = SMAInverter_SMAcommand($hash, $hash->{HOST}, 0x51000200, 0x00696E00, 0x00696E10);
}
elsif ($i eq "sup_BatteryInfo_Capac") {
Log3 $name, 5, "$name -> sup_BatteryInfo_Capac";
#($sup_BatteryInfo_IDC,$inv_BAT_IDC,$inv_BAT_IDC_A,$inv_BAT_IDC_B,$inv_BAT_IDC_C,$inv_susyid,$inv_serial) = SMAInverter_SMAcommand($hash, $hash->{HOST}, 0x51000200, 0x00496800, 0x004968FF);
@ -771,6 +857,9 @@ sub SMAInverter_getstatusDoParse($) {
elsif ($i eq "sup_SpotBatteryLoad") {
($sup_SpotBatteryLoad,$inv_BAT_LOADTODAY,$inv_BAT_LOADTOTAL,$inv_susyid,$inv_serial) = SMAInverter_SMAcommand($hash, $hash->{HOST}, 0x54000200, 0x00496700, 0x004967FF);
}
elsif ($i eq "sup_SpotBatteryUnload") {
($sup_SpotBatteryUnload,$inv_BAT_UNLOADTODAY,$inv_BAT_UNLOADTOTAL,$inv_susyid,$inv_serial) = SMAInverter_SMAcommand($hash, $hash->{HOST}, 0x54000200, 0x00496800, 0x004968FF);
}
}
# nothing more to do, just log out
@ -850,6 +939,10 @@ sub SMAInverter_getstatusDoParse($) {
if($sup_EnergyProduction) {
push(@row_array, "etotal ".($inv_SPOT_ETOTAL/1000)."\n") if ($inv_SPOT_ETOTAL ne "-");
push(@row_array, "etoday ".($inv_SPOT_ETODAY/1000)."\n") if ($inv_SPOT_ETODAY ne "-");
}
if($sup_PVEnergyProduction) {
push(@row_array, "epvtotal ".($inv_SPOT_EPVTOTAL/1000)."\n") if ($inv_SPOT_EPVTOTAL ne "-");
push(@row_array, "epvtoday ".($inv_SPOT_EPVTODAY/1000)."\n") if ($inv_SPOT_EPVTODAY ne "-");
}
if($sup_SpotDCPower) {
push(@row_array, "string_1_pdc ".sprintf("%.3f",$inv_SPOT_PDC1/1000)."\n");
@ -869,7 +962,10 @@ sub SMAInverter_getstatusDoParse($) {
push(@row_array, "state ".sprintf("%.3f",$inv_SPOT_PACTOT/1000)."\n");
}
if($sup_ChargeStatus) {
push(@row_array, "chargestatus ".$inv_ChargeStatus."\n");
push(@row_array, "chargestatus ".$inv_ChargeStatus."\n"); #TTT
}
if($sup_BatteryInfo_Capacity) {
push(@row_array, "bat_capacity ".$inv_BAT_CAPACITY."\n"); #TTT
}
if($inv_CLASS && $inv_CLASS eq 8007 && defined($inv_SPOT_PACTOT)) { # V2.10.1 28.04.2019
@ -929,6 +1025,10 @@ sub SMAInverter_getstatusDoParse($) {
push(@row_array, "bat_loadtotal ".($inv_BAT_LOADTOTAL/1000)."\n") if ($inv_BAT_LOADTOTAL ne "-");
push(@row_array, "bat_loadtoday ".($inv_BAT_LOADTODAY/1000)."\n") if ($inv_BAT_LOADTODAY ne "-");
}
if($sup_SpotBatteryUnload) {
push(@row_array, "bat_unloadtotal ".($inv_BAT_UNLOADTOTAL/1000)."\n") if ($inv_BAT_UNLOADTOTAL ne "-");
push(@row_array, "bat_unloadtoday ".($inv_BAT_UNLOADTODAY/1000)."\n") if ($inv_BAT_UNLOADTODAY ne "-");
}
}
if($detail_level > 1) {
@ -983,6 +1083,10 @@ sub SMAInverter_getstatusDoParse($) {
if($sup_EnergyProduction) {
push(@row_array, "SPOT_ETOTAL ".$inv_SPOT_ETOTAL."\n") if ($inv_SPOT_ETOTAL ne "-");
push(@row_array, "SPOT_ETODAY ".$inv_SPOT_ETODAY."\n") if ($inv_SPOT_ETODAY ne "-");
}
if($sup_PVEnergyProduction) {
push(@row_array, "SPOT_EPVTOTAL ".$inv_SPOT_EPVTOTAL."\n") if ($inv_SPOT_EPVTOTAL ne "-");
push(@row_array, "SPOT_EPVTODAY ".$inv_SPOT_EPVTODAY."\n") if ($inv_SPOT_EPVTODAY ne "-");
}
if($sup_SpotDCPower) {
push(@row_array, "SPOT_PDC1 ".$inv_SPOT_PDC1."\n");
@ -1060,6 +1164,13 @@ sub SMAInverter_getstatusDoParse($) {
push(@row_array, "BAT_LOADTOTAL ".$inv_BAT_LOADTOTAL."\n") if ($inv_BAT_LOADTOTAL ne "-");
push(@row_array, "BAT_LOADTODAY ".$inv_BAT_LOADTODAY."\n") if ($inv_BAT_LOADTODAY ne "-");
}
if($sup_BatteryInfo_Capacity) {
push(@row_array, "BAT_CAPACITY ".$inv_BAT_CAPACITY."\n") if ($inv_BAT_CAPACITY ne "-"); #TTT
}
if($sup_SpotBatteryUnload) {
push(@row_array, "BAT_UNLOADTOTAL ".$inv_BAT_UNLOADTOTAL."\n") if ($inv_BAT_UNLOADTOTAL ne "-");
push(@row_array, "BAT_UNLOADTODAY ".$inv_BAT_UNLOADTODAY."\n") if ($inv_BAT_UNLOADTODAY ne "-");
}
}
if($detail_level > 1) {
@ -1228,6 +1339,7 @@ sub SMAInverter_SMAcommand($$$$$) {
my $esignature = "0010606509A0";
my ($inv_TYPE, $inv_CLASS,
$inv_SPOT_ETODAY, $inv_SPOT_ETOTAL,
$inv_SPOT_EPVTODAY, $inv_SPOT_EPVTOTAL,
$inv_susyid,
$inv_serial,
$inv_SPOT_PDC1, $inv_SPOT_PDC2,
@ -1244,7 +1356,7 @@ sub SMAInverter_SMAcommand($$$$$) {
$inv_BAT_IDC, $inv_BAT_IDC_A, $inv_BAT_IDC_B, $inv_BAT_IDC_C,
$inv_BAT_CYCLES, $inv_BAT_CYCLES_A, $inv_BAT_CYCLES_B, $inv_BAT_CYCLES_C,
$inv_BAT_TEMP, $inv_BAT_TEMP_A, $inv_BAT_TEMP_B, $inv_BAT_TEMP_C,
$inv_BAT_LOADTODAY, $inv_BAT_LOADTOTAL,
$inv_BAT_LOADTODAY, $inv_BAT_LOADTOTAL, $inv_BAT_CAPACITY,$inv_BAT_UNLOADTODAY,$inv_BAT_UNLOADTOTAL,
$inv_SPOT_FREQ, $inv_SPOT_OPERTM, $inv_SPOT_FEEDTM, $inv_TEMP, $inv_GRIDRELAY, $inv_STATUS);
my $mysusyid = $hash->{HELPER}{MYSUSYID};
my $myserialnumber = $hash->{HELPER}{MYSERIALNUMBER};
@ -1382,6 +1494,43 @@ sub SMAInverter_SMAcommand($$$$$) {
Log3 $name, 5, "$name - Data SPOT_ETOTAL=$inv_SPOT_ETOTAL and SPOT_ETODAY=$inv_SPOT_ETODAY";
return (1,$inv_SPOT_ETODAY,$inv_SPOT_ETOTAL,$inv_susyid,$inv_serial);
}
#PV Ertrag
if($data_ID eq 0x46C3) {
if (length($data) >= 66) {
$inv_SPOT_EPVTOTAL = unpack("V*", substr($data, 62, 4));
if(($inv_SPOT_EPVTOTAL eq -2147483648) || ($inv_SPOT_EPVTOTAL eq 0xFFFFFFFF) || $inv_SPOT_EPVTOTAL <= 0) {$inv_SPOT_EPVTOTAL = "-"; }
}
else {
Log3 ($name, 3, "$name - WARNING - EPVTOTAL wasn't deliverd ... set it to \"0\" !");
$inv_SPOT_EPVTOTAL = "-";
}
$inv_SPOT_EPVTODAY = "-";
if (length($data) >= 82) {
$inv_SPOT_EPVTODAY = unpack("V*", substr ($data, 78, 4));
if(($inv_SPOT_EPVTODAY eq -2147483648) || ($inv_SPOT_EPVTODAY eq 0xFFFFFFFF) || $inv_SPOT_EPVTODAY <= 0) {$inv_SPOT_EPVTODAY = "-"; }
}
if($inv_SPOT_EPVTODAY eq "-" && $inv_SPOT_EPVTOTAL ne "-") {
# EPVTODAY wurde vom WR nicht geliefert, es wird versucht ihn zu berechnen
Log3 ($name, 3, "$name - EPVTODAY wasn't delivered from inverter, try to calculate it ...");
my $etotold = ReadingsNum($name, ".epvtotal_yesterday", 0);
if($etotold && $inv_SPOT_EPVTOTAL > $etotold) {
$inv_SPOT_EPVTODAY = $inv_SPOT_EPVTOTAL - $etotold;
Log3 ($name, 3, "$name - EPVTODAY calculated successfully !");
}
else {
Log3 ($name, 3, "$name - WARNING - unable to calculate EPVTODAY ... set it to \"0\" !");
$inv_SPOT_EPVTODAY = "-";
}
}
Log3 $name, 5, "$name - Data SPOT_EPVTOTAL=$inv_SPOT_EPVTOTAL and SPOT_EPVTODAY=$inv_SPOT_EPVTODAY";
return (1,$inv_SPOT_EPVTODAY,$inv_SPOT_EPVTOTAL,$inv_susyid,$inv_serial);
}
if($data_ID eq 0x4967) {
if (length($data) >= 66) {
@ -1420,6 +1569,43 @@ sub SMAInverter_SMAcommand($$$$$) {
return (1,$inv_BAT_LOADTODAY,$inv_BAT_LOADTOTAL,$inv_susyid,$inv_serial);
}
if($data_ID eq 0x4968) {
if (length($data) >= 66) {
$inv_BAT_UNLOADTOTAL = unpack("V*", substr($data, 62, 4));
if(($inv_BAT_UNLOADTOTAL eq -2147483648) || ($inv_BAT_UNLOADTOTAL eq 0xFFFFFFFF) || $inv_BAT_UNLOADTOTAL <= 0) {$inv_BAT_UNLOADTOTAL = "-"; }
}
else {
Log3 $name, 3, "$name - WARNING - BATTERYUNLOAD_TOTAL wasn't deliverd ... set it to \"0\" !";
$inv_BAT_UNLOADTOTAL = "-";
}
$inv_BAT_UNLOADTODAY = "-";
if (length($data) >= 82) {
$inv_BAT_UNLOADTODAY = unpack("V*", substr ($data, 78, 4));
if(($inv_BAT_UNLOADTODAY eq -2147483648) || ($inv_BAT_UNLOADTODAY eq 0xFFFFFFFF) || $inv_BAT_UNLOADTODAY <= 0) {$inv_BAT_UNLOADTODAY = "-"; }
}
if($inv_BAT_UNLOADTODAY eq "-" && $inv_BAT_UNLOADTOTAL ne "-") {
# BATTERYUNLOAD_TODAY wurde vom WR nicht geliefert, es wird versucht ihn zu berechnen
Log3 $name, 3, "$name - BATTERYUNLOAD_TODAY wasn't delivered from inverter, try to calculate it ...";
my $bultotold = ReadingsNum($name, ".bat_unloadtotal_yesterday", 0);
if($bultotold && $inv_BAT_UNLOADTOTAL > $bultotold) {
$inv_BAT_UNLOADTODAY = $inv_BAT_UNLOADTOTAL - $bultotold;
Log3 $name, 3, "$name - BATTERYUNLOAD_TODAY calculated successfully !";
}
else {
Log3 $name, 3, "$name - WARNING - unable to calculate BATTERYUNLOAD_TODAY ... set it to \"0\" !";
$inv_BAT_UNLOADTODAY = "-";
}
}
Log3 $name, 3, "$name - Data BAT_UNLOADTOTAL=$inv_BAT_UNLOADTOTAL and BAT_UNLOADTODAY=$inv_BAT_UNLOADTODAY";
return (1,$inv_BAT_UNLOADTODAY,$inv_BAT_UNLOADTOTAL,$inv_susyid,$inv_serial);
}
if($data_ID eq 0x251E) {
$inv_SPOT_PDC1 = unpack("V*", substr $data, 62, 4);
if($size < 90) {$inv_SPOT_PDC2 = 0; } else {$inv_SPOT_PDC2 = unpack("V*", substr $data, 90, 4); } # catch short response, in case PDC2 not supported
@ -1468,6 +1654,11 @@ sub SMAInverter_SMAcommand($$$$$) {
return (1,$inv_ChargeStatus,$inv_susyid,$inv_serial);
}
if($data_ID eq 0x696E) {
$inv_BAT_CAPACITY = unpack("V*", substr $data, 62, 4);
Log3 $name, 5, "$name - Found Data Battery Capacity =$inv_BAT_CAPACITY"; #TTT
return (1,$inv_BAT_CAPACITY,$inv_susyid,$inv_serial);
}
if($data_ID eq 0x451F) {
$inv_SPOT_UDC1 = unpack("l*", substr $data, 62, 4);
# catch shorter responses in case not second string supported
@ -1749,6 +1940,7 @@ sub SMAInverter_SMAlogon($$$) {
my $target_serial = AttrVal($name, "target-serial", $default_target_serial);
#Encode the password
$pass = SMAInverter_SMAdecrypt( $pass );
my $encpasswd = "888888888888888888888888"; # template for password
for my $index (0..length $pass ) # encode password
{
@ -2242,9 +2434,11 @@ The retrieval of the inverter will be executed non-blocking. You can adjust the
<li><b>BAT_UDC [A,B,C] / bat_udc [A,B,C]</b> : Battery Voltage [A,B,C]</li>
<li><b>BAT_PDC / bat_pdc</b> : Battery power (only Hybrid-Inverter)</li>
<li><b>ChargeStatus / chargestatus</b> : Battery Charge status </li>
<li><b>BAT_CAPACITY / bat_capacity</b> : Battery (remaining) Capacity (SOH)</li>
<li><b>BAT_LOADTODAY</b> : Battery Load Today </li>
<li><b>BAT_LOADTOTAL</b> : Battery Load Total </li>
<li><b>ChargeStatus / chargestatus</b> : Battery Charge status </li>
<li><b>BAT_UNLOADTODAY</b> : Battery Unload Today </li>
<li><b>BAT_UNLOADTOTAL</b> : Battery Unload Total </li>
<li><b>CLASS / device_class</b> : Inverter Class </li>
<li><b>PACMAX1 / pac_max_phase_1</b> : Nominal power in Ok Mode </li>
<li><b>PACMAX1_2 / pac_max_phase_1_2</b> : Maximum active power device (Some inverters like SB3300/SB1200) </li>
@ -2253,6 +2447,8 @@ The retrieval of the inverter will be executed non-blocking. You can adjust the
<li><b>Serialnumber / serial_number</b> : Inverter Serialnumber </li>
<li><b>SPOT_ETODAY / etoday</b> : Today yield </li>
<li><b>SPOT_ETOTAL / etotal</b> : Total yield </li>
<li><b>SPOT_EPVTODAY / epvtoday</b> : Today PV yield </li>
<li><b>SPOT_EPVTOTAL / epvtotal</b> : Total PV yield </li>
<li><b>SPOT_FEEDTM / feed-in_time</b> : Feed-in time </li>
<li><b>SPOT_FREQ / grid_freq </b> : Grid Frequency </li>
<li><b>SPOT_CosPhi / coshhi </b> : displacement factor </li>
@ -2482,8 +2678,11 @@ Die Abfrage des Wechselrichters wird non-blocking ausgeführt. Der Timeoutwert f
<li><b>BAT_UDC [A,B,C] / bat_udc [A,B,C]</b> : Akku Spannung [A,B,C]</li>
<li><b>BAT_PDC / bat_pdc</b> : Akku Leistung (bei Hybridwechselrichtern)</li>
<li><b>ChargeStatus / chargestatus</b> : Akku Ladestand </li>
<li><b>BAT_CAPACITY / bat_capacity</b> : Battery (verbleibende) Kapazität (SOH)</li>
<li><b>BAT_LOADTODAY</b> : Battery Load Today </li>
<li><b>BAT_LOADTOTAL</b> : Battery Load Total </li>
<li><b>BAT_UNLOADTODAY</b> : Battery Unload Today </li>
<li><b>BAT_UNLOADTOTAL</b> : Battery Unload Total </li>
<li><b>CLASS / device_class</b> : Wechselrichter Klasse </li>
<li><b>PACMAX1 / pac_max_phase_1</b> : Nominelle Leistung in Ok Mode </li>
<li><b>PACMAX1_2 / pac_max_phase_1_2</b> : Maximale Leistung (für einige Wechselrichtertypen) </li>
@ -2491,6 +2690,8 @@ Die Abfrage des Wechselrichters wird non-blocking ausgeführt. Der Timeoutwert f
<li><b>PACMAX3 / pac_max_phase_3</b> : Nominelle Leistung in Fault Mode </li>
<li><b>Serialnumber / serial_number</b> : Wechselrichter Seriennummer </li>
<li><b>SPOT_ETODAY / etoday</b> : Energie heute</li>
<li><b>SPOT_EPVTOTAL / epvtotal</b> : PV Energie Insgesamt </li>
<li><b>SPOT_EPVTODAY / epvtoday</b> : PV Energie heute</li>
<li><b>SPOT_ETOTAL / etotal</b> : Energie Insgesamt </li>
<li><b>SPOT_FEEDTM / feed-in_time</b> : Einspeise-Stunden </li>
<li><b>SPOT_FREQ / grid_freq </b> : Netz Frequenz </li>