77_SMAEM: contrib 3.4.0

git-svn-id: https://svn.fhem.de/fhem/trunk@19449 2b470e98-0d58-463d-a4d8-8e2adae1ed80
This commit is contained in:
nasseeder1 2019-05-22 20:33:36 +00:00
parent a75a3219ce
commit 1153cf07ac

View File

@ -36,7 +36,7 @@ eval "use FHEM::Meta;1" or my $modMetaAbsent = 1;
# Versions History done by DS_Starter
our %SMAEM_vNotesIntern = (
"3.4.0" => "22.05.2019 support of Installer.pm/Meta.pm added, new version maintenance ",
"3.4.0" => "22.05.2019 support of Installer.pm/Meta.pm added, new version maintenance, commandref revised ",
"3.3.0" => "21.05.2019 set reset to delete and reinitialize cacheFile, support of DelayedShutdownFn ",
"3.2.0" => "26.07.2018 log entry enhanced if diff overflow ",
"3.1.0" => "12.02.2018 extend error handling in define ",
@ -412,7 +412,7 @@ sub SMAEM_DoParse ($) {
# Zyklus verwerfen wenn Plausibilität nicht erfüllt
my $d = $bezug_wirk_count - $gridoutsum;
my $errtxt = "Cycle discarded due to allowed diff \"$d\" GRIDOUT exceeding. \n".
"Try to set attribute \"diffAccept > $d\" temporary.";
"Try to set attribute \"diffAccept > $d\" temporary or execute \"reset\".";
$error = encode_base64($errtxt,"");
Log3 ($name, 1, "SMAEM $name - $errtxt");
Log3 ($name, 4, "SMAEM $name -> BlockingCall SMAEM_DoParse finished");
@ -444,7 +444,7 @@ sub SMAEM_DoParse ($) {
# Zyklus verwerfen wenn Plausibilität nicht erfüllt
my $d = $einspeisung_wirk_count - $gridinsum;
my $errtxt = "Cycle discarded due to allowed diff \"$d\" GRIDIN exceeding. \n".
"Try to set attribute \"diffAccept > $d\" temporary.";
"Try to set attribute \"diffAccept > $d\" temporary or execute \"reset\".";
$error = encode_base64($errtxt,"");
Log3 ($name, 1, "SMAEM $name - $errtxt");
Log3 ($name, 4, "SMAEM $name -> BlockingCall SMAEM_DoParse finished");
@ -978,33 +978,65 @@ return;
</ul>
<br>
<br>
<a name="SMAEMset"></a>
<b>Set </b>
<ul>
<li><b>reset</b> <br>
The automatically generated file "cacheSMAEM" will be deleted. Then the file will be recreated again by the module.
This function is used to reset the device in possible case of error condition, but may be executed at all times.
</li>
<br>
</ul>
<a name="SMAEMattr"></a>
<b>Attribute</b>
<ul>
<a name="disableSernoInReading"></a>
<li><b>disableSernoInReading</b> : prevents the prefix "SMAEM&lt;serialnumber_&gt;....." </li>
<li><b>disableSernoInReading</b> <br>
prevents the prefix "SMAEM&lt;serialnumber_&gt;....."
</li>
<br>
<a name="feedinPrice"></a>
<li><b>feedinPrice</b> : the individual amount of refund of one kilowatt hour</li>
<li><b>feedinPrice</b> <br>
the individual amount of refund of one kilowatt hour
</li>
<br>
<a name="interval"></a>
<li><b>interval</b> : evaluation interval in seconds </li>
<li><b>interval</b> <br>
evaluation interval in seconds
</li>
<br>
<a name="disable"></a>
<li><b>disable</b> : 1 = the module is disabled </li>
<li><b>disable</b> <br>
1 = the module is disabled
</li>
<br>
<a name="diffAccept"></a>
<li><b>diffAccept</b> : diffAccept determines the threshold, up to that a calaculated difference between two
straight sequently meter readings (Readings with *_Diff) should be commenly accepted (default = 10). <br>
Hence faulty DB entries with a disproportional high difference values will be eliminated, don't
tamper the result and the measure cycles will be discarded. </li>
<li><b>diffAccept</b> <br>
diffAccept determines the threshold, up to that a calaculated difference between two
straight sequently meter readings (Readings with *_Diff) should be commenly accepted (default = 10). <br>
Hence faulty DB entries with a disproportional high difference values will be eliminated, don't
tamper the result and the measure cycles will be discarded.
</li>
<br>
<a name="powerCost"></a>
<li><b>powerCost</b> : the individual amount of power cost per kWh </li>
<li><b>powerCost</b> <br>
the individual amount of power cost per kWh
</li>
<br>
<a name="timeout"></a>
<li><b>timeout</b> : adjustment timeout of backgound processing (default 60s). The value of timeout has to be higher than the value of "interval". </li>
<li><b>timeout</b> <br>
adjustment timeout of backgound processing (default 60s). The value of timeout has to be higher than the value
of "interval".
</li>
<br>
</ul>
<br>
@ -1060,33 +1092,66 @@ However there are readings what maybe need some explanation. <br>
</ul>
<br>
<a name="SMAEMset"></a>
<b>Set </b>
<ul>
<li><b>reset</b> <br>
Es wird das automatisch erstellte File "cacheSMAEM" gelöscht. Das File wird durch das Modul wieder neu initialisiert
angelegt. Diese Funktion wird zur Rücksetzung eines eventuellen Fehlerzustandes des Devices verwendet, kann
aber auch jederzeit ausgeführt werden.
</li>
<br>
</ul>
<a name="SMAEMattr"></a>
<b>Attribute</b>
<ul>
<a name="disableSernoInReading"></a>
<li><b>disableSernoInReading</b> : unterdrückt das Prefix "SMAEM&lt;serialnumber_&gt;....." </li>
<li><b>disableSernoInReading</b> <br>
unterdrückt das Prefix "SMAEM&lt;serialnumber_&gt;....."
</li>
<br>
<a name="feedinPrice"></a>
<li><b>feedinPrice</b> : die individuelle Höhe der Vergütung pro Kilowattstunde </li>
<li><b>feedinPrice</b> <br>
die individuelle Höhe der Vergütung pro Kilowattstunde
</li>
<br>
<a name="interval"></a>
<li><b>interval</b> : Auswertungsinterval in Sekunden </li>
<li><b>interval</b> <br>
Auswertungsinterval in Sekunden
</li>
<br>
<a name="disable"></a>
<li><b>disable</b> : 1 = das Modul ist disabled </li>
<li><b>disable</b> <br>
1 = das Modul ist disabled
</li>
<br>
<a name="diffAccept"></a>
<li><b>diffAccept</b> : diffAccept legt fest, bis zu welchem Schwellenwert eine berechnete positive Werte-Differenz
zwischen zwei unmittelbar aufeinander folgenden Zählerwerten (Readings mit *_Diff) akzeptiert werden
soll (Standard ist 10). <br>
Damit werden eventuell fehlerhafte Differenzen mit einem unverhältnismäßig hohen Differenzwert von der Berechnung
ausgeschlossen und der Messzyklus verworfen. </li>
<li><b>diffAccept</b> <br>
diffAccept legt fest, bis zu welchem Schwellenwert eine berechnete positive Werte-Differenz
zwischen zwei unmittelbar aufeinander folgenden Zählerwerten (Readings mit *_Diff) akzeptiert werden
soll (Standard ist 10). <br>
Damit werden eventuell fehlerhafte Differenzen mit einem unverhältnismäßig hohen Differenzwert von der Berechnung
ausgeschlossen und der Messzyklus verworfen.
</li>
<br>
<a name="powerCost"></a>
<li><b>powerCost</b> : die individuelle Höhe der Stromkosten pro Kilowattstunde </li>
<li><b>powerCost</b> <br>
die individuelle Höhe der Stromkosten pro Kilowattstunde
</li>
<br>
<a name="timeout"></a>
<li><b>timeout</b> : Einstellung timeout für Hintergrundverarbeitung (default 60s). Der timeout-Wert muss größer als das Wert von "interval" sein. </li>
<li><b>timeout</b> <br>
Einstellung timeout für Hintergrundverarbeitung (default 60s). Der timeout-Wert muss größer als das Wert von
"interval" sein.
</li>
<br>
</ul>