@ -165,7 +165,7 @@ FHT_Initialize($)
|
||||
$hash->{ParseFn} = "FHT_Parse";
|
||||
$hash->{AttrList} = "IODev do_not_notify:1,0 model:fht80b dummy:1,0 " .
|
||||
"showtime:1,0 loglevel:0,1,2,3,4,5,6 retrycount " .
|
||||
"minfhtbuffer lazy tmpcorr ignore:1,0";
|
||||
"minfhtbuffer lazy tmpcorr ignore:1,0 event-on-update-reading event-on-change-reading";
|
||||
}
|
||||
|
||||
|
||||
@ -413,13 +413,37 @@ FHT_Parse($$)
|
||||
return $name;
|
||||
}
|
||||
|
||||
my $tn = TimeNow();
|
||||
|
||||
# counter for notifies
|
||||
my $nc = 0;
|
||||
#
|
||||
# special treatment for measured-temp which is actually sent in two bytes
|
||||
#
|
||||
|
||||
# the measured temperature comes in two bytes: measured-low and measured-high
|
||||
# measured-temp= (measured-high * 256 + measured-low) / 10.
|
||||
# measured-low and measured-high will only be stored as internals
|
||||
if($cmd eq "measured-low") {
|
||||
|
||||
$def->{fhem}{measuredLow}= $val;
|
||||
return "";
|
||||
|
||||
} elsif($cmd eq "measured-high") {
|
||||
|
||||
$def->{fhem}{measuredHigh}= $val;
|
||||
|
||||
if(defined($def->{fhem}{measuredLow})) {
|
||||
|
||||
$val = ($val*256.0 + $def->{fhem}{measuredLow})/10.0+ AttrVal($name, "tmpcorr", 0.0);
|
||||
$cmd = "measured-temp";
|
||||
} else {
|
||||
return "";
|
||||
}
|
||||
}
|
||||
|
||||
#
|
||||
# from here readings are effectively updated
|
||||
#
|
||||
readingsBeginUpdate($def);
|
||||
|
||||
###########################
|
||||
# Reformat the values so they are readable.
|
||||
# The first four are confirmation messages, so they must be converted to
|
||||
# the same format as the input (for the softbuffer)
|
||||
|
||||
@ -429,7 +453,7 @@ FHT_Parse($$)
|
||||
} elsif($cmd eq "mode") {
|
||||
$val = $c2m{$val} if(defined($c2m{$val}));
|
||||
|
||||
} elsif($cmd =~ m/.*-temp/) {
|
||||
} elsif($cmd =~ m/.*-temp/ && $cmd ne "measured-temp") {
|
||||
$val = sprintf("%.1f", $val / 2);
|
||||
if($cmd eq "desired-temp") {
|
||||
$val = ($val > 30 ? "on" : ($val < 6 ? "off" : $val));
|
||||
@ -457,30 +481,8 @@ FHT_Parse($$)
|
||||
|
||||
else { $val = "unknown_$sval: $fv" }
|
||||
|
||||
} elsif($cmd eq "measured-low") {
|
||||
$def->{READINGS}{$cmd}{TIME} = $tn;
|
||||
$def->{READINGS}{$cmd}{VAL} = $val;
|
||||
return "";
|
||||
|
||||
} elsif($cmd eq "measured-high") {
|
||||
$def->{READINGS}{$cmd}{TIME} = $tn;
|
||||
$def->{READINGS}{$cmd}{VAL} = $val;
|
||||
|
||||
if(defined($def->{READINGS}{"measured-low"}) &&
|
||||
defined($def->{READINGS}{"measured-low"}{VAL})) {
|
||||
|
||||
my $off = ($attr{$name} && $attr{$name}{tmpcorr}) ?
|
||||
$attr{$name}{tmpcorr} : 0;
|
||||
$val = $val*256 + $def->{READINGS}{"measured-low"}{VAL};
|
||||
$val /= 10;
|
||||
$val = sprintf("%.1f (Celsius)", $val+$off);
|
||||
$cmd = "measured-temp";
|
||||
|
||||
} else {
|
||||
return "";
|
||||
}
|
||||
|
||||
} elsif($cmd eq "warnings") {
|
||||
|
||||
my $nVal;
|
||||
|
||||
# initialize values for additional warnings
|
||||
@ -519,43 +521,37 @@ FHT_Parse($$)
|
||||
$val = $nVal? $nVal : "none";
|
||||
|
||||
# set additional warnings and trigger notify
|
||||
$def->{READINGS}{'battery'}{TIME} = $tn;
|
||||
$def->{READINGS}{'battery'}{VAL} = $valBattery;
|
||||
$def->{CHANGED}[$nc] = "battery: $valBattery";
|
||||
readingsUpdate($def, "battery", $valBattery);
|
||||
Log $ll4, "FHT $name battery: $valBattery";
|
||||
$nc++;
|
||||
|
||||
$def->{READINGS}{'lowtemp'}{TIME} = $tn;
|
||||
$def->{READINGS}{'lowtemp'}{VAL} = $valLowTemp;
|
||||
$def->{CHANGED}[$nc] = "lowtemp: $valLowTemp";
|
||||
readingsUpdate($def, "lowtemp", $valLowTemp);
|
||||
Log $ll4, "FHT $name lowtemp: $valLowTemp";
|
||||
$nc++;
|
||||
|
||||
$def->{READINGS}{'window'}{TIME} = $tn;
|
||||
$def->{READINGS}{'window'}{VAL} = $valWindow;
|
||||
$def->{CHANGED}[$nc] = "window: $valWindow";
|
||||
readingsUpdate($def, "window", $valWindow);
|
||||
Log $ll4, "FHT $name window: $valWindow";
|
||||
$nc++;
|
||||
|
||||
$def->{READINGS}{'windowsensor'}{TIME} = $tn;
|
||||
$def->{READINGS}{'windowsensor'}{VAL} = $valSensor;
|
||||
$def->{CHANGED}[$nc] = "windowsensor: $valSensor";
|
||||
readingsUpdate($def, "windowsensor", $valSensor);
|
||||
Log $ll4, "FHT $name windowsensor: $valSensor";
|
||||
$nc++;
|
||||
}
|
||||
|
||||
if(substr($msg,24,1) eq "7") { # Do not store FHZ acks.
|
||||
$cmd = "FHZ:$cmd";
|
||||
|
||||
} else {
|
||||
$def->{READINGS}{$cmd}{TIME} = $tn;
|
||||
$def->{READINGS}{$cmd}{VAL} = $val;
|
||||
$def->{STATE} = "$cmd: $val" if($cmd eq "measured-temp");
|
||||
readingsUpdate($def, $cmd, $val);
|
||||
if($cmd eq "measured-temp") {
|
||||
$def->{STATE} = "$cmd: $val";
|
||||
readingsUpdate($def, "temperature", $val);
|
||||
}
|
||||
}
|
||||
$def->{CHANGED}[$nc] = "$cmd: $val";
|
||||
|
||||
Log $ll4, "FHT $name $cmd: $val";
|
||||
|
||||
#
|
||||
# now we are done with updating readings
|
||||
#
|
||||
readingsEndUpdate($def, 0);
|
||||
|
||||
################################
|
||||
# Softbuffer: delete confirmed commands
|
||||
if($confirm) {
|
||||
@ -577,7 +573,7 @@ FHT_Parse($$)
|
||||
return $name;
|
||||
}
|
||||
|
||||
|
||||
#####################################
|
||||
# Check the softwarebuffer and send/resend commands
|
||||
sub
|
||||
doSoftBuffer($)
|
||||
|
Loading…