2
0
mirror of https://github.com/fhem/fhem-mirror.git synced 2025-03-10 03:06:37 +00:00

10_EnOcean: subType actuator.01 modified

git-svn-id: https://svn.fhem.de/fhem/trunk@11697 2b470e98-0d58-463d-a4d8-8e2adae1ed80
This commit is contained in:
klaus-schauer 2016-06-19 19:29:52 +00:00
parent 0128b6a9b0
commit 0e44196056

View File

@ -1,6 +1,7 @@
##############################################
# $Id$
# 2016-06-18
package main;
@ -1251,28 +1252,55 @@ sub EnOcean_Get($@)
Log3 $name, 3, "EnOcean get $name $cmd $channel";
$data = sprintf "%02X%02X", $cmdID, $channel;
} elsif ($cmd eq "special" && $manufID eq "033") {
} elsif ($cmd eq "special") {
$rorg = "D1";
my $query = shift(@a);
if (!defined $query) {
return "$cmd <channel> <query> wrong, choose health|load|voltage|serialNumber.";
} elsif ($query eq "health") {
$query = 7;
} elsif ($query eq "load") {
$query = 8;
} elsif ($query eq "voltage") {
$query = 9;
} elsif ($query eq "serialNumber") {
$query = 0x81;
} else {
return "$cmd <channel> <query> wrong, choose health|load|voltage|serialNumber.";
if ($manufID eq "033") {
if (!defined $query) {
return "$cmd <channel> <query> wrong, choose health|load|voltage|serialNumber.";
} elsif ($query eq "health") {
$query = 7;
} elsif ($query eq "load") {
$query = 8;
} elsif ($query eq "voltage") {
$query = 9;
} elsif ($query eq "serialNumber") {
$query = 0x81;
} else {
return "$cmd <channel> <query> wrong, choose health|load|voltage|serialNumber.";
}
$data = sprintf "0331%02X", $query;
Log3 $name, 3, "EnOcean get $name $cmd $channel $query";
readingsSingleUpdate($hash, "getParam", $query, 0);
} elsif ($manufID eq "046") {
if (!defined $query) {
return "$cmd <channel> <query> wrong, choose reset|firmwareVersion|taughtInDevNum|taughtInDevID.";
} elsif ($query eq "reset") {
$query = 1;
$data = sprintf "0046%02X", $query;
} elsif ($query eq "firmwareVersion") {
$query = 2;
$data = sprintf "0046%02X", $query;
} elsif ($query eq "taughtInDevNum") {
$query = 4;
$data = sprintf "0046%02X", $query;
} elsif ($query eq "taughtInDevID") {
$query = 6;
my $taughtInDevNum = shift(@a);
if (defined $taughtInDevNum && $taughtInDevNum =~ m/^\d+$/ && $taughtInDevNum >= 0 && $taughtInDevNum <= 23) {
$data = sprintf "0046%02X%02X", $query, $taughtInDevNum;
} else {
return "Usage: taughtInDevID is not numeric or out of range";
}
} else {
return "$cmd <channel> <query> wrong, choose reset|firmwareVersion|taughtInDevNum|taughtInDevID.";
}
Log3 $name, 3, "EnOcean get $name $cmd $channel $query";
readingsSingleUpdate($hash, "getParam", $query, 0);
}
Log3 $name, 3, "EnOcean get $name $cmd $channel $query";
$data = sprintf "0331%02X", $query;
readingsSingleUpdate($hash, "getParam", $query, 0);
} else {
if ($manufID eq "033") {
if ($manufID =~ m/^033|046$/) {
return "Unknown argument $cmd, choose one of " . $cmdList . "state measurement roomCtrlMode:noArg special settings";
} else {
return "Unknown argument $cmd, choose one of " . $cmdList . "state measurement roomCtrlMode:noArg settings";
@ -4462,8 +4490,40 @@ sub EnOcean_Set($@)
}
$data = sprintf "%02X%02XFFFFFFFF%02X", $cmdID, $channel, $extSwitchMode << 6 | $extSwitchType << 5;
} elsif ($cmd eq "special") {
$rorg = "D1";
shift(@a);
$updateState = 0;
my $repeaterActive = 0;
my $repeaterLevel = 0;
my $specialCmd = shift(@a);
if ($manufID eq "046") {
if (!defined $specialCmd) {
return "$cmd <command> wrong, choose repeaterLevel.";
} elsif ($specialCmd eq "repeaterLevel") {
$cmdID = 8;
my $repeaterLevel = shift(@a);
if (defined $repeaterLevel && $repeaterLevel =~ m/^off|1|2$/) {
if ($repeaterLevel eq "off") {
$repeaterLevel = 0;
} else {
$repeaterActive = 1;
}
} else {
return "Usage: repeaterLevel is wrong";
}
} else {
return "$cmd $specialCmd <arg> wrong, choose repeaterLevel off|1|2.";
}
}
$data = sprintf "0046%02X%02X%02X", $cmdID, $repeaterActive, $repeaterLevel;
} else {
$cmdList .= "dim:slider,0,1,100 on off autoOffTime delayOffTime extSwitchMode extSwitchType local measurement roomCtrlMode:off,buildingProtection,economy,comfort-2,comfort-1,comfort";
if ($manufID =~ m/^046$/) {
$cmdList .= "dim:slider,0,1,100 on off autoOffTime delayOffTime extSwitchMode extSwitchType local measurement roomCtrlMode:off,buildingProtection,economy,comfort-2,comfort-1,comfort special";
} else {
$cmdList .= "dim:slider,0,1,100 on off autoOffTime delayOffTime extSwitchMode extSwitchType local measurement roomCtrlMode:off,buildingProtection,economy,comfort-2,comfort-1,comfort";
}
return SetExtensions ($hash, $cmdList, $name, @a);
}
Log3 $name, 3, "EnOcean set $name $cmd";
@ -10224,41 +10284,53 @@ sub EnOcean_Parse($$)
} elsif ($rorg eq "D1") {
# MSC telegram
if ($st eq "actuator.01" && $manufID eq "033") {
if (substr($data, 3, 1) == 4) {
my $getParam = ReadingsVal($name, "getParam", 0);
if ($getParam == 8) {
push @event, "3:loadClassification:no";
push @event, "3:loadLink:" . ($db[1] & 16 ? "connected" : "disconnected");
push @event, "3:loadOperation:3-wire";
push @event, "3:loadState:" . ($db[1] & 64 ? "on" : "off");
CommandDeleteReading(undef, "$name getParam");
} elsif ($getParam == 7) {
if ($db[0] & 4) {
push @event, "3:devTempState:warning";
} elsif ($db[0] & 2) {
push @event, "3:devTempState:max";
} else {
push @event, "3:devTempState:ok";
if ($st eq "actuator.01") {
if ($manufID eq "033") {
if (substr($data, 3, 1) == 4) {
my $getParam = ReadingsVal($name, "getParam", 0);
if ($getParam == 8) {
push @event, "3:loadClassification:no";
push @event, "3:loadLink:" . ($db[1] & 16 ? "connected" : "disconnected");
push @event, "3:loadOperation:3-wire";
push @event, "3:loadState:" . ($db[1] & 64 ? "on" : "off");
CommandDeleteReading(undef, "$name getParam");
} elsif ($getParam == 7) {
if ($db[0] & 4) {
push @event, "3:devTempState:warning";
} elsif ($db[0] & 2) {
push @event, "3:devTempState:max";
} else {
push @event, "3:devTempState:ok";
}
push @event, "3:mainsPower:" . ($db[0] & 8 ? "failure" : "ok");
if ($db[1] == 0xFF) {
push @event, "3:devTemp:invalid";
} else {
push @event, "3:devTemp:" . $db[1];
}
CommandDeleteReading(undef, "$name getParam");
} elsif ($getParam == 9) {
push @event, "3:voltage:" . sprintf("%.2f", (hex(substr($data, 4, 4)) * 0.01));
CommandDeleteReading(undef, "$name getParam");
} elsif ($getParam == 0x81) {
$hash->{READINGS}{serialNumber}{VAL} = substr($data, 4, 4);
$hash->{READINGS}{getParam}{VAL} = 0x82;
EnOcean_SndRadio(undef, $hash, $packetType, "D1", "033182", AttrVal($name, "subDef", "00000000"), "00", $hash->{DEF});
} elsif ($getParam == 0x82) {
push @event, "3:serialNumber:" . $hash->{READINGS}{serialNumber}{VAL} . substr($data, 4, 4);
CommandDeleteReading(undef, "$name getParam");
}
push @event, "3:mainsPower:" . ($db[0] & 8 ? "failure" : "ok");
if ($db[1] == 0xFF) {
push @event, "3:devTemp:invalid";
} else {
push @event, "3:devTemp:" . $db[1];
}
CommandDeleteReading(undef, "$name getParam");
} elsif ($getParam == 9) {
push @event, "3:voltage:" . sprintf("%.2f", (hex(substr($data, 4, 4)) * 0.01));
CommandDeleteReading(undef, "$name getParam");
} elsif ($getParam == 0x81) {
$hash->{READINGS}{serialNumber}{VAL} = substr($data, 4, 4);
$hash->{READINGS}{getParam}{VAL} = 0x82;
EnOcean_SndRadio(undef, $hash, $packetType, "D1", "033182", AttrVal($name, "subDef", "00000000"), "00", $hash->{DEF});
} elsif ($getParam == 0x82) {
push @event, "3:serialNumber:" . $hash->{READINGS}{serialNumber}{VAL} . substr($data, 4, 4);
CommandDeleteReading(undef, "$name getParam");
}
} elsif ($manufID eq "046") {
my $cmd = hex(substr($data, 4, 2));
if ($cmd == 3) {
push @event, "3:firmwareVersion:" . substr($data, 6, 6);
} elsif ($cmd == 5) {
push @event, "3:taughtInDevNum:$db[0]";
} elsif ($cmd == 7) {
CommandDeleteReading(undef, "$name taughtInDevID.*");
push @event, "3:taughtInDevID" . sprintf('%02d', $db[4]) . ":" . substr($data, 8, 8);
}
}
} elsif ($st eq "raw") {
@ -15009,7 +15081,7 @@ EnOcean_Delete($$)
Therefore, the approach does not only define parameters for the value recalculation algorithm
but also includes specific signal definition. (e.g. physical units). Further technical
information can be found at the
<a href="https://www.enocean-alliance.org/fileadmin/redaktion/enocean_alliance/pdf/GenericProfiles_V1_Extract.pdf">Generic Profiles 1.0 Abstract (PDF)</a>
<a href="https://www.enocean-alliance.org/fileadmin/redaktion/enocean_alliance/pdf/GenericProfiles_V1_Extract.pdf">Generic Profiles 1.0 Abstract</a>
<br><br>
Smart Acknowledge (Smart Ack) enables a special bidirectional communication. The communication is managed by a
Controller that responds to the devices telegrams with acknowledges. Smart Ack is a bidirectional communication
@ -16302,6 +16374,9 @@ EnOcean_Delete($$)
specify the measurement unit</li>
<li>roomCtrlMode off|comfort|comfort-1|comfort-2|economy|buildingProtection<br>
set pilot wire mode</li>
<li>special repeater off|1|2<br>
set repeater level of device (additional NodOn command)
</li>
</ul><br>
[autoOffTime] = 0 s ... 0.1 s ... 6553.4 s<br>
[delayOffTime] = 0 s ... 0.1 s ... 6553.4 s<br>
@ -16714,6 +16789,9 @@ EnOcean_Delete($$)
<li>special &lt;channel&gt; health|load|voltage|serialNumber<br>
additional Permondo SmartPlug PSC234 commands
</li>
<li>special &lt;channel&gt; firmwareVersion|reset|taughtInDevID|taughtInDevNum<br>
additional NodOn commands
</li>
</ul><br>
The default channel can be specified with the attr <a href="#EnOcean_defaultChannel">defaultChannel</a>.<br>
@ -18763,6 +18841,7 @@ EnOcean_Delete($$)
<li>error&lt;channel&gt;: ok|warning|failure|not_supported</li>
<li>extSwitchMode&lt;1...29|All|Input&gt;: unavailable|switch|pushbutton|auto</li>
<li>extSwitchType&lt;1...29|All|Input&gt;: toggle|direction</li>
<li>firmwareVersion: [000000 ... FFFFFF]</li>
<li>loadClassification: no</li>
<li>localControl&lt;channel&gt;: enabled|disabled</li>
<li>loadLink: connected|disconnected</li>
@ -18785,6 +18864,8 @@ EnOcean_Delete($$)
<li>responseTimeMin: 1/s</li>
<li>roomCtrlMode: off|comfort|comfort-1|comfort-2|economy|buildingProtection</li>
<li>serialNumber: [00000000 ... FFFFFFFF]</li>
<li>taughtInDevID&lt;00...23&gt;: [00000001 ... FFFFFFFE]</li>
<li>taughtInDevNum: [0 ... 23]</li>
<li>teach: &lt;result of teach procedure&gt;</li>
<li>teachInDev: enabled|disabled</li>
<li>state: on|off</li>